Axis Communications AXIS Q1755-E user manual LED indicators

Page 42

AXIS Q1755/-E - Unit connectors

Digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for exam- ple: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under Events > Port Status.)

Notes:

The I/O connector on AXIS Q1755-E is connected to the housing electronics at delivery and will trigger an input port event to indicate a fan or heater error when activated. See Events, on page 25, for information on how to set up an event.

For information on how to connect external devices, refer to the Installation Guide supplied with the product.

Function

Pin number

Notes

Specifications

 

 

 

 

GND

1

Ground

 

 

 

 

 

3.3V DC Power

2

Can be used to power auxiliary equipment.

Max load = 250mA

 

 

Note:

 

 

 

This pin can only be used as power out.

 

 

 

 

 

Configurable

3 - 4

Digital input - Connect to GND to activate, or leave

Min input = - 40V DC

(Input or Output)

 

floating (or unconnected) to deactivate.

Max input = + 40V DC

 

 

AXIS Q1755-E: Connected to housing electronics at

 

 

 

delivery.

 

 

 

 

 

 

 

Digital output - Uses an open-drain NFET transistor

Max load = 100mA

 

 

with the source connected to GND. If used with an

Max voltage = + 40V DC

 

 

external relay, a diode must be connected in parallel

 

 

 

with the load, for protection against voltage tran-

 

 

 

sients.

 

 

 

 

 

Power connector - 3-pin terminal block 8-20 VDC or 20-24 VAC.

 

 

 

 

 

 

 

+ ~

 

 

 

 

LED indicators

 

 

 

 

 

 

~

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED

Color

Indication

 

 

 

 

 

 

 

 

 

 

 

Network

Green

Steady for connection to a 100 Mbit/s network. Flashes for network activity.

 

 

 

 

 

 

 

 

 

 

 

 

Amber

Steady for connection to 10 Mbit/s network. Flashes for network activity.

 

 

 

 

 

 

 

 

 

 

 

 

Unlit

No network connection.

 

 

 

 

 

 

 

 

 

 

 

Status

Green

Steady green for normal operation.

 

 

 

Note: The Status LED can be configured to be unlit during normal operation, or to flash

 

 

 

only when the camera is accessed. To configure, go to Setup > System Options > LED.

 

 

 

See the online help files for more information.

 

 

 

 

 

 

 

 

 

 

 

 

Amber

Steady during startup, during reset to factory default or when restoring settings.

 

 

 

 

 

 

 

 

 

 

 

 

Red

Slow flash for failed upgrade.

 

 

 

 

 

 

 

 

 

 

 

Power

Green

Normal operation.

 

 

 

 

 

 

 

 

 

 

 

 

Amber

Flashes green/amber during firmware upgrade.

 

 

 

 

 

 

 

 

 

 

Note:

Please refer to the product’s Installation Guide for information on the LED indicators for the housing electronics (fan/heater).

42

Image 42
Contents USER’S Manual Axis Q1755/-E User’s Manual Axis Q1755/-E Table of contents Contents Key features Product DescriptionAxis Q1755/-E Product Description Overview Rear view Bottom viewAlarm output connected at delivery Axis Q1755-EAccessing the Camera Access from a browserAxis Q1755/-E Accessing the Camera Setting the root password Access from the internetClick the Create self-signed certificate button General controls Setup Events GatekeeperLive View Axis Media Control toolbarHalf-duplex mode AMC Audio controlsHow to stream H.264 Video StreamsAxis Q1755/-E Video Streams Axis Q1755/-E Video Streams Axis Media Control AMC Alternative methods of accessing the video streamMotion Jpeg Unicast via Rtsp axrtsp//ip/axis-media/media.ampBasic Setup Axis Q1755/-E Basic SetupVideo & Audio Video StreamAudio Axis Q1755/-E Video & Audio Text Overlay Settings264 GOV Settings Bit Rate ControlStream Profiles Camera SettingsExposure Settings White balanceFocus and zoom Overlay ImagePrivacy mask Audio Channels Audio SettingsAudio mode The available audio modes are Audio InputAxis Q1755/-E Video & Audio Audio Output Default Viewer Live View ConfigAxis Q1755/-E Live View Config LayoutUser Defined Links Viewer SettingsAction Buttons Other browsersAxis Q1755/-E Live View Config Output Buttons Advanced Pan/Tilt Preset PositionsPTZ Pan Tilt Zoom DeviceEnable/Disable controls Control Queue SettingsPanel Shortcut Command Buttons ControlsEvent Types EventsEvent Servers Axis Q1755/-E EventsAxis Q1755/-E Events Triggered Event How to set up a triggered eventFollowing example describes how to set up a triggered event Save streamGatekeeper How to set up a scheduled eventSettings Camera tamperingMotion Detection Set up a motion detection include windowAfter you define these settings, click Save Go to Events Motion DetectionPort Status ExamplesRecording List Axis Q1755/-E Recording ListRemove button is used to delete unlocked recordings Axis Q1755/-E System Options System OptionsSecurity UsersAudio Support Axis Q1755/-E System Options IeeeCertificates IPv4 Address Configuration Basic TCP/IP SettingsNetwork Settings Date & TimeServices Advanced TCP/IP SettingsIPv6 Address Configuration DNS ConfigurationHttp and Https LAN intranetLink-Local IPv4 Address NAT traversal port mapping for IPv4Snmp v1/v2 QoS Quality of ServiceSmtp email As the Internet. See the online help for more informationStorage Ports & DevicesLED Settings MaintenanceSupport Advanced Plain ConfigConfiguration File UploadAbout Resetting to the Factory Default SettingsUsing the Control Button Axis Q1755/-E AboutUnit connectors Axis Q1755/-E Unit connectorsLED indicators Emergency Recovery Procedure TroubleshootingAxis Q1755/-E Troubleshooting Checking the FirmwareAxis Q1755/-E Troubleshooting Axis Support Router to allow access to the camera Installation GuideGuide or the ARP/Ping commands Check the Internet firewall with your system administratorSet to Decode only I frames Existing files to free up space Volume settings are correctServer. This is enabled under System Options Date & Time NanceTechnical Specifications Axis Q1755/-E Technical SpecificationsSystem Application Alarm triggersAlarm events Integration ProgrammingDimensions PowerConnectors WeightGeneral performance considerations Glossary of Terms Axis Q1755/-E Glossary of TermsEtrax Ethernet Token Ring Axis Axis own microprocessor Half-duplex See Full-duplexMAC address Media Access Control address a MAC VOP See VOPAxis Q1755/-E Glossary of Terms URL Uniform Resource Locator An address on the network More secure the encryption Active/Inactive 22 Alarm 28, 41 AMC 7 ARP/Ping 34 Audio Backup Bit Rate Bonjour Buffer SizeAxis Q1755/-E Index Video Stream