Bosch Appliances NDN-832 Maintenance, Testing the network connection, Data Terminal

Page 42

42 en Maintenance

FlexiDomeHD 1080p IP Camera

 

 

9Maintenance

9.1Testing the network connection

The ping command can be used to check the connection between two IP addresses. This allows testing whether a device is active in the network.

1.Open the DOS command prompt.

2.Type ping followed by the IP address of the device.

If the device is found, the response appears as " Reply from ... ", followed by the number of bytes sent and the transmission time in milliseconds. Otherwise, the device cannot be accessed via the network. This might be because:

The device is not properly connected to the network. Check the cable connections in this case.

The device is not correctly integrated into the network. Check the IP address, subnet mask, and gateway address.

9.2Communication with Terminal Program

Data Terminal

If a camera cannot be found in the network or the connection to the network is interrupted, you can connect a data terminal to the camera for initial setup and for setting important parameters. The data terminal consists of a computer with a terminal program.

You require a serial transmission cable to connect to the computer.

The communications accessory included with Windows can be used as the terminal program.

1.Disconnect the camera from the Ethernet network before working with the terminal program.

2.Connect the serial interface of the camera using any available serial interface on the computer.

AM18-Q0601 v1.0 2012.01

Installation Manual

Bosch Security Systems

Image 42
Contents FlexiDomeHD 1080p IP Camera Page Table of Contents Troubleshooting InstallationCamera configuration MaintenanceTechnical Data 10.1 Specifications 10.1.1 DimensionsSafety Safety precautionsImportant safety instructions Connection in applications Type labelGrounding FCC & Ices compliance FCC & Ices InformationMicroSD cards UL certificationDisclaimer Bosch notices Copyrights Features IntroductionSystem Information Overview of functionsAudio Alarm I/OPower-over-Ethernet Tamper detection and motion detectionConfiguration EncryptionRecording Bosch Video Client Operation with external systemsBosch Video Management System Bosch Recording StationPlanning UnpackingSystem requirements Installation PartsMounting the unit Surface mountingFlexiDomeHD 1080p IP Camera Installation en Flush mount Figure?5.2?Flush mountingFlexiDomeHD 1080p IP Camera Installation en Connections Wire colorSignal Make the connectionsPower connection Alarm InputNetwork and PoE connection Alarm output Audio in / Audio outMount the camera module M 1 N-mOpening the camera module Controls Camera set-up Camera positioning 1 PanTilt Twist Using the install wizard Adjustment procedureClosing the unit Camera configuration Day/Night switchingBrowser connection Protected networkTroubleshooting Function testResolving problems Malfunction Possible causes SolutionLivepage Functions Customer service For example 192.168.0.80/versionCommunication with Terminal Program MaintenanceTesting the network connection Data TerminalAssigning an IP Address Configuring the TerminalCommand Inputs 192.168.0.1Transfer and disposal RebootRepairs Additional ParametersTechnical Data SpecificationsIP, IBP, Ibbp 10.1.1 Dimensions En Technical Data FlexiDomeHD 1080p IP Camera Page Bosch Security Systems