8 en Safety | FlexiDomeHD 1080p IP Camera |
|
|
1.3Connection in applications
Grounding
The yellow/green safety (power) ground wire from the camera must be connected to the system earth of the installation. U.S.A.: - section 810 of the National Electrical Code, ANSI/NFPA No.70, provides information regarding proper grounding.
12 VDC / 24 VAC power source: This unit is intended to operate with a limited power source. The unit is intended to operate at either 12 VDC or 24 VAC (if PoE is not available). User supplied wiring must be in compliance with electrical codes (Class 2 power levels).
PoE: Use only approved PoE devices.
If auxiliary power (12 VDC or 24 VAC) and PoE is applied simultaneously, the camera selects auxiliary input and shuts off the PoE.
1.4Type label
The type label is located on the rear of the camera module.
Installation Manual | Bosch Security Systems |