Cisco Systems CIVS-IPC-2621V manual Maintenance Window, Section on

Page 56

Chapter 3 Configuring and Managing the IP Camera

Administration Windows

Maintenance Window

The Maintenance window provides options for resetting or restarting the IP camera, saving configuration information from the IP camera, and uploading the configuration information to the IP camera.

Saving and uploading configuration is useful for these activities:

Configuring multiple IP cameras—If your network includes several IP cameras that should have similar configurations, you can configure one IP camera, save that configuration, and upload it to other IP cameras. Then, instead of manually configuring all options on each IP camera, you manually configure only the options that are unique, such as the IP address, if not obtained from DHCP.

Backing up configuration—If you save the configuration from the IP camera, you can upload it to the IP camera to restore the configuration if it is lost, or if you can upload it to a replacement IP camera, if needed.

To display the Maintenance window, access the configuration windows as described in the “Accessing the IP Camera Windows” section on page 2-25, click Administration, then click Maintenance.

Table 3-7describes the options in the Maintenance window.

Table 3-7 Maintenance Window Options

Option

Description

 

 

Restore Factory

Click the Restore button to restore all IP camera settings to their factory

Defaults

default values.

 

To confirm the restore procedure, click OK in the confirmation pop-up

 

window. Otherwise, click Cancel.

 

This action has the same effect as pressing and holding the Reset button on

 

the IP camera for at least 10 seconds. After you perform this procedure,

 

follow the steps in the “Performing the Initial Setup of the IP Camera”

 

section on page 2-23.

 

 

Restart

Click the Restart button to reboot the software on IP camera.

 

To confirm the restart procedure, click OK in the confirmation pop-up

 

window. Otherwise, click Cancel.

 

This action has the same effect as pressing and immediately releasing the

 

Reset button on the IP camera, or powering the IP camera down and then

 

powering it up.

 

 

Configuration

Click the Save button to save the current IP camera configuration

 

information to a binary file.

 

When you click this button, the File Download window appears. Use this

 

window to save the configuration file. This file must include the

 

extension .cfg.

 

You can then upload this configuration information to any IP camera in the

 

network. This feature is useful for creating a backup of this configuration

 

and for configuring other IP cameras based on this configuration.

 

 

 

Cisco Video Surveillance System 2621 IP Dome User Guide

3-14

OL-24129-02

Image 56
Contents Cisco Video Surveillance 2621 IP Dome User Guide Americas HeadquartersCisco Video Surveillance System 2621 IP Dome User Guide N T E N T S Using the IP Camera with Cisco VSM Overview OrganizationViii Features Features, IP Camera Overview,Physical Details, Package Contents, IP Camera OverviewPhysical Details Top of the 2621 IP DomeOverview IP Camera Overview Described in the Resetting the IP Camera section on Bottom of the 2621 IP DomePackage Contents Getting Started Before You BeginPreventing Electrostatic Discharge Damage Installing the Cisco Video Surveillance 2621 IP DomePreparing for Installation, Mounting with a Junction Box, Preparing for Installation Passing the Audio Cable through a Ferrite CoreProcedure Mounting with a Junction BoxDisassembling the 2621 IP Dome Components Attaching the Base Plate to a Junction Box Attaching the Camera Unit to the Base Plate Cisco Video Surveillance System 2621 IP Dome User Guide Mounting with a Conduit Base Attaching the Privacy Shield and DomeBase plate Camera unit Camera unit screws Attaching the Conduit Base to a Surface Attaching the Base Plate to the Conduit Base See -1 on Cisco Video Surveillance System 2621 IP Dome User Guide 10 Attaching the Privacy Shield and Dome Mounting to a Ceiling Tile 11 Disassembling the 2621 IP Dome Components 12 Preparing the 2621 IP Dome Ceiling Tile See -1 on Mounting on a Solid Surface 13 Securing Torx Screws14 Disassembling the 2621 IP Dome Components See -1 on Performing the Initial Setup of the IP Camera 15 Securing Torx ScrewsProtocol//ipaddress Accessing the IP Camera Windows Https//192.168.0.100Https//203.70.212.521024 Http//203.70.212.52Adjusting the Video Image Http//203.70.212.52102416 Adjusting the Camera Lens on the 2621 IP Dome Powering the IP Camera On or Off Resetting the IP CameraReset Type Procedure Remarks Initial Setup of the IP CameraCleaning the IP Camera OL-24129-02 Configuring and Managing the IP Camera Configuration OverviewConfiguration Item Explanation Guidelines for Use Reference See the Alarm I/O Ports See the Audio Window sectionSee the Privacy Region See the Focus/Zoom WindowNavigating the Configuration Windows SnmpSetup Windows Basic Setup WindowDevice Settings Option DescriptionOption Description Advanced Setup Window Network SettingsOption BonjourOption Description IP Filter Window QoS EAP-FAST Options Eapol Window EAP-TLS Options Users Window Administration WindowsUsers Window, Maintenance Window, Firmware Window, Administrator User ListMaintenance Window Firmware Window Audio/Video Windows Video WindowDual Streams MPEG-4 + Mjpeg -Configures MPEG-4 for SettingsMPEG-4 Settings Mjpeg Settings Resolution Choose the resolution of the Mjpeg video streamVideo Adjustment PAL/50 HzOptions Day/Night VisionOption Description Duplex Talk and Listen Audio WindowControls section on Privacy Region Window Focus/Zoom WindowChoose Simplex Talk Only , Half Duplex Talk or Listen , or Full Duplex Talk and ListenInitialization Window, Complexity Window, Security WindowsInitialization Window Complexity Window Users Window section onApplications Windows Mail/FTP/HTTP WindowDescribed in the Basic Setup Window section on Mail SetupPrimary Smtp Server Secondary Smtp ServerMail Body Primary FTPSecondary FTP Http NotificationMotion Detection Window System-provided-name-value-pairs is the event informationEvent Window Event Schedule New ScheduleClear button Trigger EventMail/FTP/HTTP Window section on AttachmentSnmp Window Alarm I/O Ports Window Alarm Input SettingsAlarm Output Settings Manual Control SettingsSystem Status Status WindowsSystem Window Audio Setting Audio/Video WindowNetwork Window Syslog & Log WindowLocal Log Sys Log ServerSystem log messages Log ListMessage Explanation Syslog and Log Information Address Address1 Port1 Address2 Port2 , User FTP log messagesVideo Log Window Smtp log messagesDelete button Delete All buttonOL-24129-02 Viewing Video through the Home Window Overview Home Window OverviewHome Window Home Window Controls Control DescriptionDigital zoom controls Audio controlsSnapshot controls SaveIP camera controls For related information, see the Video Window section onViewing Video through Third-Party Devices or Software Accessing the Primary H.264 StreamAccessing Secondary H.264 Stream Accessing the Primary MPEG-4 Stream Accessing Dual MPEG-4 StreamsAccessing the Mjpeg Stream Accessing Dual Streams H.264 + MjpegAccessing Dual Streams MPEG-4 + Mjpeg OL-24129-02 Troubleshooting Troubleshooting Using the IP Camera with Cisco VSM For instructions, see the Video Window section onOL-24129-02 D E IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8
Related manuals
Manual 108 pages 3.3 Kb