Dakota Digital 3 BUS Interface Module Setup, Information Menu, Odometer Preset Menu

Page 26

BUS INTERFACE MODULE SETUP

The bus interface modules (BIM) are a future product added to Dakota Digital instrumentation systems. They allow you to add auxiliary gauge functions, such as fuel pressure, vac/boost, trans temp, etc., right into the system without having to add additional gauges. All of the BIM readings are displayed on the tachometer message display where the tachometer and other performance readings are currently displayed. Switch 2 (SW2) is used to cycle through the various message screens.

More detailed instructions are supplied with the BIM units.

INFORMATION MENU

The information menu, “INFO” is used to display software code information should you have any troubles, this information can be useful for troubleshooting as well as the current speedometer calibration value if using the normal speed input (SPD SND).

Press and hold SW 1 while turning the key on.

Release the switch and then press and release SW1 to get to the “INFO” setup menu. You should see “SExx” on the speedometer display where xx is the software number.

To view the current pulse per mile (PPM) setting, press and hold the SW1 until -INFO” is displayed.

Release the switch and the odometer will show the current PPM setting/calibration value.

Press and release the switch to go on to the next setup menu.

ODOMETER PRESET MENU

The control box will allow you to set the odometer miles to match your current odometer reading, ONE time within the first 100 miles. Once the odometer has more than 100 miles, this menu option will no longer be displayed. Make sure you have correctly selected the units to be either MPH or km/h and calibrated your speedometer first. The odometer will be set in the selected units. Once you have preset the miles you cannot change it again without sending to the factory.

WARNING!!: This only allows setting odometer to the nearest mile. Do not use tenths! For example a mileage of 65432.1 should be set to “ 065432using this method. If the tenths digit is used, the odometer will read 10 times too high.

Press and hold SW 1 while turning the key on.

Release the switch and then press and release SW1 to get to the -ODOM setup menu.

Press and hold the switch until -ODOM” is displayed to enter the odometer setup menu, then release SW1. ” “. The current miles will be displayed on the odometer with the left most digit flashing.

Press and release SW1 to increment the digit. Press and hold the switch to move to the next digit to the right.

Continue until the right most digit has been set. Press and hold the switch and the speed display will show “ NO

If the value is incorrect press and hold the switch while “ NO” is displayed to go back and change the odometer miles or turn the key off to cancel any changes.

If the value is correct press and release the switch to change to speed display to “YES”.

Press and hold the switch while “YES” is displayed to save the current odometer reading and return to the setup menus.

26

MAN 650066:D

Image 26
Contents Series NOW with Solid State Sensor TechnologyTypical Display Setups Mounting Single Lens Systems Mounting Universal Display Systems with SubpanelsMounting Systems with Displays Mounted to Aluminum Mounting Kits Into Original Dashes Complete Systems mounted in new bezelGauge System Features Message Displays DescriptionWiring the control box into the vehicle Control BOX MountingGround Terminal DescriptionsStatus LED Warn PowerTach DIMSPD SPD +SPD SND SPD OUTADJ SW 1 or Speed switchADJ SND WTR SNDOIL SND WTROIL + OILCruise Fuel SNDFuel Wait +Right + BrakeDisplay Ribbon Cable Check ENGAUX. I/O Setting up the control box Speedometer SETUP/CALIBRATION Speed sensor setup SenderMAN 650066D Engine cylinder setup T-CAL Tachometer SetupExit setup Done Speed Output OutputRpm warning setup Warn Volt SetupDisplay update setup Update Tach signal setup SignalTemp warning setup Warn Water Temp SetupTemp sensor setup Sender Oil pressure warning setup Warn OIL Pressure SetupExit water temp setup Done Temp sensor test TestOil pressure sensor test Test Fuel SetupExit oil pressure setup Done Fuel sensor setup Sender Exit fuel setup Done Performance Menu SetupNighttime DIM Setup Information Menu BUS Interface Module SetupOdometer Preset Menu Troubleshooting Guide MAN 650066D MAN 650066D Clock Instructions For VFD systems with a clock built Troubleshooting guide Service and Repair