Bosch Appliances D6600 installation and operation guide D6100IPv6 I&O Guide

Page 62

62 en Network Communications

Conettix Communications Receiver/

Gateway

 

 

 

Config

Config

Config

Default

Valid Values

Description

Section

Sub-

Parameter

Value

 

 

 

section

 

 

 

 

 

 

 

 

 

 

interface

eth0

default

<None

Accepts in

If IPv4 DHCP is disabled, enter the IPv4

 

 

gateway

>

IPv4 address

Gateway IP Address.

 

 

 

 

in dotted

 

 

 

 

 

notation

 

 

 

 

 

(192.168.1.1)

 

 

 

 

 

 

 

interface

eth0

dhcpv6

enable

enable, disable

Determines if IPv6 DHCP is used. If this is set

 

 

 

 

 

to disabled, then a Static IPv6 Address needs

 

 

 

 

 

to be specified in the IP Address

 

 

 

 

 

Configuration Parameter.

 

 

 

 

 

 

interface

eth0

ipv6

<None

Accepts an

If IPv6 DHCP is disabled, then an IPv6

 

 

address

>

IPv6 address

Address must be entered here.

 

 

 

 

 

 

interface

eth0

ipv6

<None

Accepts an

If IPv6 DHCP is disabled, enter the IPv6

 

 

default

>

IPv6 address

Gateway IP Address.

 

 

gateway

 

in colon

 

 

 

 

 

notation

 

 

 

 

 

(2001:0db8:85

 

 

 

 

 

a3:0042:0000:

 

 

 

 

 

8a2e:

 

 

 

 

 

0370:7334)

 

 

 

 

 

 

 

interface

eth0

hostname

 

 

Sets the hostname that is used with DHCP.

 

 

 

 

 

 

oem

 

mac

 

 

Allows for an alternate MAC Address to be

 

 

address

 

 

entered here supporting the failover

 

 

 

 

 

configuration described in the D6600/

 

 

 

 

 

D6100IPv6 I&O Guide (4998122704).

 

 

 

 

 

 

device

 

short

D6686

 

Sets the product short name displayed in

 

 

name

 

 

command mode. (Max of 8 Characters)

 

 

 

 

 

 

device

 

long name

Bosch

 

Sets the product long name displayed in

 

 

 

D6686

 

command mode.

 

 

 

 

 

 

bosch tunnel

1 or 2

local port

7700

 

IP Port number the D6686 is listening on for

 

 

 

(tunnel

 

IP traffic relative to each serial port. See the

 

 

 

1) / 7701

 

failover configuration described in the D6600/

 

 

 

(tunnel 2)

 

D6100IPv6 I&O Guide (4998122704).

 

 

 

 

 

 

bosch tunnel

1 or 2

protocol

UDP

UDP, UDP AES

Determines the protocol to be used

 

 

 

 

 

depending whether encryption is being used.

 

 

 

 

 

(See Important Note on next page)

 

 

 

 

 

 

bosch tunnel

1 or 2

aes key

128

128, 192, 256

Determines the Encryption Key Size in

 

 

size

 

 

number of bits.

 

 

 

 

 

 

2012.11 08 4998122704

Installation and Operation Guide

Bosch Security Systems, Inc.

Image 62
Contents Conettix Communications Receiver/Gate- way Page Table of contents Central Station Automation System Central Station Tips Network CommunicationsNo Data Received Reports Troubleshooting Guide Specifications Service Information Emergency Procedures Before CallingBosch Security Systems, Inc. Product Manufacturing Dates IntroductionAbout documentation En Introduction Conettix Communications Receiver Gateway 3System overview D6600/D6100IPv6 Supported Communication FormatsConettix D6100IPv6 System Components Parts ListConettix D6600 System Components Quick Installation D6600Automation PC and External Parallel Printer Connections AC Power and Telephone ConnectionsCallout ᅳ Description Date Setup D6600/D6100IPv6 Setting the Time and DateTime Setup D6600/D6100IPv6 Card Functions and Locations D6600 Front PanelName Model Description Line Cards and ModulesSystem Trouble LED Status Solid Red or Yellow Clear D6600 Rear View D6600 Communications Receiver/Gateway Rear ViewReceiver Card Placement D6600 Internal ViewD6100IPv6 Front Panel D6100IPv6 Rear ViewD6600 Specific Cards D6640/D6641 Line Cards and D6645 Line Terminator CardsFlash Pattern Color Function Card InstallationD6640/D6641 LED Descriptions Installing Terminator Cards Installing Line CardsD6610 CPU Card and D6615 CPU Terminator Card D6640/D6641 Telephone Line MonitoringReplacing the CPU Card Card Removal and ReplacementRemoving the CPU Card Printer Specifications Shipment D6600 only InstallationInstallation Check List Removing Power to the Receiver Rack Mount InstructionsStandby Power PowerPower Supply Modules Main Power Connecting External BatteriesMinimum Standby Battery Device Qty Battery Standby UPS AC Standby CurrentMinimum Standby UPS Power Estimated BTU LoadUPS Monitoring through CPU Programmable Input Ports Input and Output Ports10.1 Overview of Input and Output Ports Input Default Connection Configuration Input Reverse Connection ConfigurationTerminator Card Configuration D6600/D6100IPv6 Operation 11.1 Process FlowReporting Devices Primary and Secondary How Call Groups WorkBuzzer Operation 11.2 Normal Operation Mode 11.3 Operating in Manual ModeLog Using the Keypad11.4 Keypad Menu Operation Event Buffer DisplaySoftware Version Display Keypad FunctionsLCD/LED Availability Test Function Busy Seconds Line Busy ReportsClear Pending Events Function Two-Way Audio SIAEnhancements and Changes Two-Way Auto Modes of OperationPage Network Communications PlementPanel NIC Callout ᅳ Description Setting Up the Host Computer 12.1 Conettix D6600/D6100IPv6 Pre-installation RequirementsHost Computer for Conettix D6600/D6100IPv6 System Setup OperationProtocol TCP/IP Select Start → Settings → Control PanelDouble-clickLocal Area connection Network administrator Page Page Network Failover Solution D6600 Only COM1 COM4Callout Description Conettix Datagram Type Differences Networking and Encryption Internal IP Address Source PortUpgrading Encryption Using Encryption for the First TimeUsing Two D6686/D6682/D6680 Modules in a System 12.3 Special Conettix D6600 Applications Obtaining the Latest D6200CD SoftwareD6680/D6682 No 12.4 D6100IPv6 Configuration Setup Instructions12.4.1 Factory Default IP Address 12.4.3 Obtaining an IP Address 12.4.4 Using the D6200 to configure the D6100IPv6Identifying the MAC Hardware Address FTP User Name admin FTP Password Pass Page Cidr D6100IPv6 I&O Guide 12.4.5 Configuring for Network Communication 12.5.2 Obtaining an IP Address 12.5 D6100i Configuration Setup Instructions12.5.1 Identifying the MAC Hardware Address EnterArp -s xxx.xxx.xxx.xxx zz-zz-zz-zz-zz-zz Initial IP Address Assignment Using ARP.EXESelect Start → Run Select Turn Windows Features on or off Using Telnet to Finish the ConfigurationSelect Programs and Features Click StartControl PanelProgramsConfiguration Using Telnet Page Steps below, type the correct value and press Enter Press Enter1Enter 12.5.6 Configuring for Network CommunicationPress Down to view the 6.2 Network adapter and press Enter Press Down to view 6.3.6 Network Automation Output FormatPress Enter to view 6.4.1 IP Address 13.1 No Data Received 13.2 Data ErrorNo Data Received Reports 13.3 Wrong DataCentral Station Automation System Receiver system Direct ConnectReceiver System Standard/Network Automation Central Station Tips 15.6 Radio Frequency Interference 15.7 Test CommunicatorTroubleshooting Guide Symptom Problem SolutionPage Symptom Problem Solution Specifications LED Psdn D6600 and D6100IPv6 Listings and Approvals Service Information Emergency Data SheetReceiver Connected to Computer System? Yes No Page Page Bosch Security Systems, Inc
Related manuals
Manual 168 pages 55.61 Kb Manual 4 pages 782 b

D6600 specifications

Bosch Appliances is renowned for its innovative and high-quality home appliances, and the Bosch D6600 dishwasher perfectly embodies these values. Designed with the user in mind, the D6600 offers an exceptional cleaning experience combined with advanced technologies and practical features.

One of the standout features of the Bosch D6600 is its outstanding energy efficiency. It boasts an Energy Star certification, ensuring that it operates with minimal energy consumption while still delivering powerful cleaning performance. This not only helps reduce monthly utility bills but also makes it an environmentally friendly choice for consumers looking to minimize their carbon footprint.

The D6600 employs Bosch’s advanced PrecisionWash technology, which uses intelligent sensors to continually scan and determine the level of dirtiness of dishes. This ensures that the dishwasher adjusts its wash cycles accordingly, providing a customized cleaning approach. This system guarantees thorough cleaning of even the toughest food residues, leaving dishes sparkling clean every time.

Quiet operation is another defining characteristic of the Bosch D6600. At just 44 dBA, it is one of the quietest dishwashers in its class, making it an ideal choice for open-concept living spaces or homes where noise is a concern. This level of noise is achieved thanks to Bosch’s insulation technology, which minimizes vibrations and sound emissions.

The dishwasher features a spacious and flexible interior, designed with Bosch’s RackMatic system. This innovative rack adjustment technology allows users to easily customize the loading capacity based on their needs. The top rack can be adjusted to three different heights, accommodating taller items in the bottom rack or larger cookware in the upper storage area.

Another highlight of the Bosch D6600 is its smart technology capabilities. Compatible with Home Connect, this feature enables users to control their dishwasher remotely via a smartphone app. Users can start cycles, receive notifications when the washing is complete, and even diagnose issues, enhancing convenience and user experience.

In addition to its efficient cleaning capabilities and user-friendly features, the Bosch D6600 also includes a robust sanitation option. The Sanitize feature raises water temperature to eliminate 99.9% of bacteria, ensuring that dishes not only look clean but are thoroughly sanitized.

With its combination of cutting-edge technology, energy efficiency, and thoughtful design, the Bosch D6600 dishwasher represents an outstanding choice for consumers seeking reliability and performance in their kitchen appliances. Whether washing everyday dishes or entertaining guests, this dishwasher exceeds expectations.