Bosch Appliances D6600 Steps below, type the correct value and press Enter

Page 69

Conettix Communications Receiver/

Network Communications en 69

Gateway

 

 

 

i

Notice!

If the default value displayed in your Telnet window does not match the value listed in any of

 

the steps below, type the correct value and press Enter.

1.At the Baud Rate prompt, press Enter to accept the default (38400).

2.At the I/F Mode prompt, press Enter to accept the default (4C).

3.At the Flow prompt, press Enter to accept the default (00).

4.Type a unique Port Number for the LAN to which the D6100i is connected and press

Enter.

5.At the ConnectMode prompt, press Enter to accept the default (CC).

6.At the Datagram Type prompt, type 00 or 02 and press Enter.

7.At the IP addr prompt, type the remote IP address used for the D6600 to which the C900V2 reports and press Enter.

8.Enter the remote IP address using 000.000.000.000 format.

9.Type the Port Number for the D6600 and press Enter.

If you want to enable encryption, continue with the next step, or skip ahead to the last step.

i

Notice!

If encryption is enabled on the D6100i, it must be enabled on all field devices.

 

1.From the Change Setup menu, type 6 and press Enter. This information appears.

2.At the Disable SNMP prompt, press Enter to accept the default (N).

3.At the SNMP Community Name prompt, press Enter to accept the default (blank).

4.At the Disable Telnet Setup prompt, press Enter to accept the default (N).

5.At the Disable Port 77FEh prompt, press Enter to accept the default (N).

Bosch Security Systems, Inc.

Installation and Operation Guide

2012.11 08 4998122704

Image 69
Contents Conettix Communications Receiver/Gate- way Page Table of contents Network Communications No Data Received ReportsCentral Station Automation System Central Station Tips Troubleshooting Guide Specifications Service Information Before Calling Emergency ProceduresIntroduction About documentationBosch Security Systems, Inc. Product Manufacturing Dates En Introduction Conettix Communications Receiver Gateway D6600/D6100IPv6 Supported Communication Formats 3System overviewParts List Conettix D6600 System ComponentsConettix D6100IPv6 System Components D6600 Quick InstallationAC Power and Telephone Connections Callout ᅳ DescriptionAutomation PC and External Parallel Printer Connections Setting the Time and Date Time Setup D6600/D6100IPv6Date Setup D6600/D6100IPv6 D6600 Front Panel Card Functions and LocationsLine Cards and Modules System Trouble LED Status Solid Red or Yellow ClearName Model Description D6600 Communications Receiver/Gateway Rear View D6600 Rear ViewD6600 Internal View Receiver Card PlacementD6100IPv6 Rear View D6100IPv6 Front PanelD6640/D6641 Line Cards and D6645 Line Terminator Cards D6600 Specific CardsCard Installation D6640/D6641 LED DescriptionsFlash Pattern Color Function Installing Line Cards Installing Terminator CardsD6640/D6641 Telephone Line Monitoring D6610 CPU Card and D6615 CPU Terminator CardCard Removal and Replacement Removing the CPU CardReplacing the CPU Card Printer Specifications Installation Installation Check ListShipment D6600 only Rack Mount Instructions Removing Power to the ReceiverPower Supply Modules Main Power PowerStandby Power Connecting External BatteriesDevice Qty Battery Standby UPS AC Standby Current Minimum Standby BatteryEstimated BTU Load Minimum Standby UPS PowerInput and Output Ports 10.1 Overview of Input and Output PortsUPS Monitoring through CPU Programmable Input Ports Input Reverse Connection Configuration Input Default Connection ConfigurationTerminator Card Configuration 11.1 Process Flow D6600/D6100IPv6 OperationHow Call Groups Work Buzzer OperationReporting Devices Primary and Secondary 11.3 Operating in Manual Mode 11.2 Normal Operation Mode11.4 Keypad Menu Operation Using the KeypadLog Event Buffer DisplayKeypad Functions Software Version DisplayBusy Seconds Line Busy Reports Clear Pending Events FunctionLCD/LED Availability Test Function SIA Two-Way AudioTwo-Way Auto Modes of Operation Enhancements and ChangesPage Plement Network CommunicationsPanel NIC Callout ᅳ Description Host Computer for Conettix D6600/D6100IPv6 System Setup 12.1 Conettix D6600/D6100IPv6 Pre-installation RequirementsSetting Up the Host Computer OperationSelect Start → Settings → Control Panel Double-clickLocal Area connectionProtocol TCP/IP Network administrator Page Page COM1 COM4 Network Failover Solution D6600 OnlyCallout Description Conettix Datagram Type Differences Internal IP Address Source Port Networking and EncryptionUsing Encryption for the First Time Using Two D6686/D6682/D6680 Modules in a SystemUpgrading Encryption Obtaining the Latest D6200CD Software 12.3 Special Conettix D6600 Applications12.4 D6100IPv6 Configuration Setup Instructions 12.4.1 Factory Default IP AddressD6680/D6682 No 12.4.4 Using the D6200 to configure the D6100IPv6 Identifying the MAC Hardware Address12.4.3 Obtaining an IP Address FTP User Name admin FTP Password Pass Page Cidr D6100IPv6 I&O Guide 12.4.5 Configuring for Network Communication 12.5.1 Identifying the MAC Hardware Address 12.5 D6100i Configuration Setup Instructions12.5.2 Obtaining an IP Address EnterInitial IP Address Assignment Using ARP.EXE Select Start → RunArp -s xxx.xxx.xxx.xxx zz-zz-zz-zz-zz-zz Select Programs and Features Using Telnet to Finish the ConfigurationSelect Turn Windows Features on or off Click StartControl PanelProgramsConfiguration Using Telnet Page Steps below, type the correct value and press Enter Press Down to view the 6.2 Network adapter and press Enter 12.5.6 Configuring for Network CommunicationPress Enter1Enter Press Down to view 6.3.6 Network Automation Output FormatPress Enter to view 6.4.1 IP Address No Data Received Reports 13.2 Data Error13.1 No Data Received 13.3 Wrong DataReceiver system Direct Connect Central Station Automation SystemReceiver System Standard/Network Automation Central Station Tips 15.7 Test Communicator 15.6 Radio Frequency InterferenceSymptom Problem Solution Troubleshooting GuidePage Symptom Problem Solution Specifications LED Psdn D6600 and D6100IPv6 Listings and Approvals Emergency Data Sheet Service InformationReceiver Connected to Computer System? Yes No Page Page Bosch Security Systems, Inc
Related manuals
Manual 168 pages 55.61 Kb Manual 4 pages 782 b

D6600 specifications

Bosch Appliances is renowned for its innovative and high-quality home appliances, and the Bosch D6600 dishwasher perfectly embodies these values. Designed with the user in mind, the D6600 offers an exceptional cleaning experience combined with advanced technologies and practical features.

One of the standout features of the Bosch D6600 is its outstanding energy efficiency. It boasts an Energy Star certification, ensuring that it operates with minimal energy consumption while still delivering powerful cleaning performance. This not only helps reduce monthly utility bills but also makes it an environmentally friendly choice for consumers looking to minimize their carbon footprint.

The D6600 employs Bosch’s advanced PrecisionWash technology, which uses intelligent sensors to continually scan and determine the level of dirtiness of dishes. This ensures that the dishwasher adjusts its wash cycles accordingly, providing a customized cleaning approach. This system guarantees thorough cleaning of even the toughest food residues, leaving dishes sparkling clean every time.

Quiet operation is another defining characteristic of the Bosch D6600. At just 44 dBA, it is one of the quietest dishwashers in its class, making it an ideal choice for open-concept living spaces or homes where noise is a concern. This level of noise is achieved thanks to Bosch’s insulation technology, which minimizes vibrations and sound emissions.

The dishwasher features a spacious and flexible interior, designed with Bosch’s RackMatic system. This innovative rack adjustment technology allows users to easily customize the loading capacity based on their needs. The top rack can be adjusted to three different heights, accommodating taller items in the bottom rack or larger cookware in the upper storage area.

Another highlight of the Bosch D6600 is its smart technology capabilities. Compatible with Home Connect, this feature enables users to control their dishwasher remotely via a smartphone app. Users can start cycles, receive notifications when the washing is complete, and even diagnose issues, enhancing convenience and user experience.

In addition to its efficient cleaning capabilities and user-friendly features, the Bosch D6600 also includes a robust sanitation option. The Sanitize feature raises water temperature to eliminate 99.9% of bacteria, ensuring that dishes not only look clean but are thoroughly sanitized.

With its combination of cutting-edge technology, energy efficiency, and thoughtful design, the Bosch D6600 dishwasher represents an outstanding choice for consumers seeking reliability and performance in their kitchen appliances. Whether washing everyday dishes or entertaining guests, this dishwasher exceeds expectations.