GE HE500TIU103, IC300TIU201, IC300TIU101, HE500TIU100, HE500TIU050, HE500TIU113 manual Equipment Needed

Page 8

 

CH.1: INTRODUCTION

06 Apr 2000

 

PAGE 9

 

 

 

 

 

 

GFK-1819

 

 

 

 

 

 

 

 

 

Animated Bitmaps

No

No

No

Standard

 

 

Alarms and Status

Standard

Standard

Standard

Standard

 

 

pages

 

 

 

 

 

 

Numeric keys

Standard

No

Standard

Standard

 

 

System keys

4

4

4

4

 

 

Function keys *

10

No

12

18

 

 

LED's

No

No

No

10

 

 

SmartStack option

No

No

No

Standard

 

 

Battery Back Ram +

Optional

Optional

Optional

Standard

 

 

Real Time Clock

 

 

 

 

 

 

Comprehensive

No

1024 lines

1024 lines

1024 lines

 

 

Math's Facilities

 

 

 

 

 

 

Day & Time

No

Standard

Standard

Standard

 

 

Scheduling,

 

 

 

 

 

 

Background Task

 

 

 

 

 

 

Internal Registers

No

1024 %R

1024 %R

1024 %R

 

 

Operating

0 to 50

0 to 50

0 to 50

0 to 50

 

 

Temperature C°

 

 

 

 

 

 

Storage Temperature

-10 to 70

-10 to 70

-10 to 70

-10 to 70

 

 

 

 

 

 

 

 

Humidity Non

10-90%

10-90%

10-90%

10-90%

 

 

Condensing Storage

 

 

 

 

 

 

Environmental

Yes

Yes

Yes

Yes

 

 

NEMA4 / IP65

 

 

 

 

 

 

Y2K Certified CE

Yes

Yes

Yes

Yes

 

 

Approved

 

 

 

 

 

 

Size -Width ,Height

180 X 120 X 60

121 X 105 X 38

172 X 105 X 38

281 X 192 X 58

 

 

,Depth mm

 

 

 

 

 

 

Cut-out -- Width ,

151 X 89

100 X 85

153 X 85

242 X 158

 

 

Height mm

 

 

 

 

 

 

Screen dimensions

80 X 17

70 X 38

70 X 38

130 X 75

 

 

mm

 

 

 

 

 

 

Input Voltage Range

9-35 Vdc

9-35 Vdc

9-35 Vdc

9-35 Vdc

 

 

Weight (grams)

325

370

450

1855

 

 

Network-

No

Optional

Optional

Optional

 

 

DeviceNet, CsCAN

 

 

 

 

 

 

Data xfer from

No

Optional

Optional

Optional

 

 

Automated device

 

 

 

 

 

 

via network -

 

 

 

 

 

 

Profibus

 

 

 

 

 

*System keys can be programmed to be function keys at specific times in the project. See Function keys in CBREEZE Software Manual MAN0023

**The TIU100/110 is available with two non-standard features: 20mA current loop communication and a real-time clock (RTC). Both can be ordered at the time of purchase. The current loop can be re-fit by the user later. The RTC requires factor re-fit. The TIU050 is only available with the real-time clock option.

***The TIU20X provides for the display of both text and full graphics and has a Numeric/Function Keypad. It also allows the use of a wide range of SmartStack I/O options.

1.2Equipment Needed

1.

The current version of CBREEZEsoftware install on a PC running Windows 95, Windows 98or

 

Windows NT.

2.

TIU050/10X/11X/20X Interface Unit.

Image 8
Contents Operator Station Hardware Manual Preface 06 Apr About Programming ExamplesDeclaration of EMC Conformity Table of Contents Networks Operator Station OS Product Line Fanuc Channels IntroductionScope CH Introduction Equipment Needed CH Introduction 06 Apr GFK-1819 Technical Specifications Parameter Conditions Min Typical Max UnitsGFK-1819 Upgrade Revision Software & Firmware Software UpgradeFirmware Upgrade Scope06 Apr GFK-1819 CH Introduction CH.2 TIU050 06 Apr GFK-1819 TIU050 Contrast AdjustmentTIU050 06 Apr CH TIU050 GFK-1819 TIU050 Ports 1 TIU050 Configuration of the RS-485 PortConfiguration Bank TIU050 Dimensions TIU050 Cutout06 Apr CH TIU050 GFK-1819 TIU10X Contrast Adjustment CH TIU100/101/102/103 06 Apr GFK-181906 Apr CH.3 TIU100/101/102/103 GFK-1819 Tiux Rear View Rear View of TIU100/101/102 TIU100 Ports1 TIU10X Configuration of the RS-485 Port Automation Equipment Port Receive Transmit LEDsTIU10X Dimensions 06 Apr CH.3 TIU100/101/102/103 GFK-1819TIU11X Contrast Adjustment CH TIU110/111/112/113 06 Apr GFK-181906 Apr CH TIU110/111/112/113 GFK-1819 TIU11X Rear View Rear View of TIU11X TIU110 PortsSerial P ort 06 Apr CH TIU110/111/112/113 GFK-1819 1 TIU11X Configuration of the RS-485 PortTIU11X Dimensions CH TIU200/201/202/203 06 Apr GFK-1819 Front View of TIU20X TIU20X Button Selection ActionsRear View of TIU20X TIU20X Ports Automated Equipment Serial PortLED’s flash when the TIU20X Is communicating with the AE 06 Apr CH TIU200/201/202/203 GFK-1819 1 TIU20X Configuration of the RS-485 PortTIU20X Dimensions Communications PC to Operator Station CommunicationsRecommended Automation Equipment Communication Cables RS-232 ConnectionGFK-1819 RS-422/485 Four-Wire TIU110/10006 Apr GFK-1819 RS-485 Two-Wire GFK-1819 Current Loop + SRGetting Started Self-TestProtocol Name Software Revision Terminal Type Select Update TIU Protocol from the File menuGFK-1819 Updating the Protocol CsCAN Network Overview NetworksScope Controller Area Network can Overview DeviceNet Features DeviceNet OverviewDeviceNet Protocol DeviceNet OperationGFK-1819 Can Wiring Rules Can Network CablingProfibus Wiring 06 Apr GFK-1819 ProfibusE term in atio n H m Installing and Removing a SmartStack Module Installing SmartStack ModulesSmartstack  Removing SmartStack ModulesCH Smartstack