GE HE500TIU200, IC300TIU201 Introduction, Scope, Operator Station OS Product Line Fanuc Channels

Page 6

CH.1: INTRODUCTION

06 Apr 2000

PAGE 7

 

 

GFK-1819

CHAPTER 1: INTRODUCTION

1.1Scope

The Operator Station (TIU050/10X/11X/20X) is an Operator Station (OS) that provides extensive monitoring and control in an extremely small package. The Operator Station “OS” product line offers four distinct categories of products as described in Table 1.1.

Table 1.1 – Operator Station (OS) Product Line

Note: Only IC300 TIU101 / IC300 TIU111 IC300 TIU201 models are available through GE

Fanuc Channels.

 

Model

 

Description

 

 

TIU050: Text Only

 

 

 

 

HE500TIU050-001

2 lines x 20 characters.

 

 

HE500TIU050-002

2 lines x 20 characters with Real Time Clock.

 

 

TIU10x: Text / Semi-Graphics

 

 

 

HE500TIU100-01

8

Lines x 20 Characters plus 128 x 64 pixels.

 

 

HE500TIU100-02

8

Lines x 20 Characters plus 128 x 64 pixels with Real Time Clock.

 

 

HE500TIU100-03

8

Lines x 20 Characters plus 128 x 64 pixels with Current Loop.

 

 

HE500TIU100-04

8

Lines x 20 Characters plus 128 x 64 pixels with Current Loop and Real

 

 

HE500TIU100-05

Time Clock.

 

 

8

Lines x 20 Characters plus 128 x 64 pixels with Stud Type Metalwork

 

 

HE500TIU100-06

8

Lines x 20 Characters plus 128 x 64 pixels with wide temperature

 

 

HE500TIU100-07

display.

 

 

8

Lines x 20 Characters plus 128 x 64 pixels with Bezel

 

 

HE500TIU100-09

8

Lines x 20 Characters plus 128 x 64 pixels with no metal and dill

 

 

 

connectors

 

 

IC300TIU101-01

8

Lines x 20 Characters plus 128 x 64 pixels with CsCAN Network.

 

 

 

8

Lines x 20 Characters plus 128 x 64 pixels with CsCAN Network and

 

 

IC300TIU101-02

Real Time Clock.

 

 

HE500TIU102-01

8

Lines x 20 Characters plus 128 x 64 pixels with a ProfibusNetwork.

 

 

HE500TIU102-02

8

Lines x 20 Characters plus 128 x 64 pixels with ProfibusNetwork

 

 

and Real Time Clock.

 

 

HE500TIU103-01

8

Lines x 20 Characters plus 128 x 64 pixels with DeviceNet

 

 

HE500TIU103-02

Networks.

 

 

8

Lines x 20 Characters plus 128 x 64 pixels with DeviceNet

 

 

 

Networks and Real Time Clock.

 

 

TIU11X: Text / Semi Graphics with Numeric Keypad

 

 

HE500TIU110-01

8

Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad.

 

 

HE500TIU110-02

8

Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with

 

 

HE500TIU110-03

Real Time Clock.

 

 

8

Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with

 

 

HE500TIU110-04

Current Loop.

 

 

8

Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with

 

 

HE500TIU110-05

Current Loop and Real Time Clock.

 

 

8

Lines x 20 Characters plus 128 x 64 pixels with Stud Type Metalwork.

 

 

HE500TIU110-06

8

Lines x 20 Characters plus 128 x 64 pixels with wide temperature

 

 

HE500TIU110-07

display.

 

 

8

Lines x 20 Characters plus 128 x 64 pixels with Bezel

 

 

HE500TIU110-09

8

Lines x 20 Characters plus 128 x 64 pixels with no metal and dill

 

 

 

connectors

 

 

IC300TIU111-01

8

Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with

 

 

 

CsCAN Network.

 

 

IC300TIU111-02

8

Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with

 

 

 

CsCAN Network and Real Time Clock.

 

 

HE500TIU112-01

8

Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with

 

 

HE500TIU112-02

ProfibusNetwork.

 

 

8

Lines x 20 Characters plus 128 x 64 pixels plus a Numeric keypad with

 

 

 

ProfibusNetwork and Real Time Clock.

 

Image 6
Contents Operator Station Hardware Manual Preface About Programming Examples Declaration of EMC Conformity06 Apr Table of Contents Networks Introduction ScopeOperator Station OS Product Line Fanuc Channels CH Introduction Equipment Needed CH Introduction 06 Apr GFK-1819 Technical Specifications Parameter Conditions Min Typical Max UnitsFirmware Upgrade GFK-1819 Upgrade Revision Software & FirmwareSoftware Upgrade Scope06 Apr GFK-1819 CH Introduction TIU050 Contrast Adjustment TIU050CH.2 TIU050 06 Apr GFK-1819 1 TIU050 Configuration of the RS-485 Port Configuration Bank06 Apr CH TIU050 GFK-1819 TIU050 Ports TIU050 Dimensions TIU050 Cutout06 Apr CH TIU050 GFK-1819 TIU10X Contrast Adjustment CH TIU100/101/102/103 06 Apr GFK-181906 Apr CH.3 TIU100/101/102/103 GFK-1819 Tiux Rear View Rear View of TIU100/101/102 TIU100 Ports1 TIU10X Configuration of the RS-485 Port Automation Equipment Port Receive Transmit LEDsTIU10X Dimensions 06 Apr CH.3 TIU100/101/102/103 GFK-1819TIU11X Contrast Adjustment CH TIU110/111/112/113 06 Apr GFK-181906 Apr CH TIU110/111/112/113 GFK-1819 TIU11X Rear View Rear View of TIU11X TIU110 PortsSerial P ort 1 TIU11X Configuration of the RS-485 Port TIU11X Dimensions06 Apr CH TIU110/111/112/113 GFK-1819 CH TIU200/201/202/203 06 Apr GFK-1819 Front View of TIU20X TIU20X Button Selection ActionsRear View of TIU20X TIU20X Ports Automated Equipment Serial PortLED’s flash when the TIU20X Is communicating with the AE 1 TIU20X Configuration of the RS-485 Port TIU20X Dimensions06 Apr CH TIU200/201/202/203 GFK-1819 Recommended Automation Equipment Communication Cables CommunicationsPC to Operator Station Communications RS-232 ConnectionGFK-1819 RS-422/485 Four-Wire TIU110/10006 Apr GFK-1819 RS-485 Two-Wire GFK-1819 Current Loop + SRGetting Started Self-TestSelect Update TIU Protocol from the File menu GFK-1819 Updating the ProtocolProtocol Name Software Revision Terminal Type Networks Scope Controller Area Network can OverviewCsCAN Network Overview DeviceNet Features DeviceNet OverviewDeviceNet Protocol DeviceNet OperationGFK-1819 Can Wiring Rules Can Network CablingProfibus Wiring 06 Apr GFK-1819 ProfibusE term in atio n H m Smartstack  Installing and Removing a SmartStack ModuleInstalling SmartStack Modules Removing SmartStack ModulesCH Smartstack