Weslo 1750 manual Symptom the Heart Rate Monitor does not Function Properly, Unplug the Power Cord

Page 21

4. SYMPTOM: THE HEART RATE MONITOR DOES NOT FUNCTION PROPERLY

a. See

How to Use the CardioTrack Heart Rate Monitor

on pages 8 and 9, and

Pulse Display

on page 13.

5. SYMPTOM: THE WALKING BELT IS OFF-CENTER WHEN WALKED ON

a.

If the walking belt has shifted to the left

, first remove the key

 

and

UNPLUG THE POWER CORD

. Using the included allen

 

wrench, turn the left rear roller adjustment bolt clockwise, and

 

the right bolt counterclockwise, 1/4 of a turn each. Be careful not

 

to overtighten the walking belt. Plug in the power cord, insert the

 

key and run the treadmill for a few minutes. Repeat until the

 

walking belt is centered.

 

b.

If the walking belt has shifted to the right

, first remove the

 

key and

UNPLUG THE POWER CORD

. Using the allen wrench,

 

turn the left rear roller adjustment bolt counterclockwise, and the

 

right bolt clockwise, 1/4 of a turn each. Be careful not to over-

 

tighten the walking belt. Plug in the power cord, insert the key

 

and run the treadmill for a few minutes. Repeat until the walking

 

belt is centered.

 

c.

If the walking belt slips when walked on

, first remove the key

 

and

UNPLUG THE POWER CORD

. Using the allen wrench, turn

 

both rear roller adjustment bolts clockwise, 1/4 of a turn. When

 

the walking belt is correctly tightened, you should be able to lift

 

the edges

of the walking belt 3 to 4 inches off the walking plat-

form. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few min- utes. Repeat until the walking belt is properly tightened.

a

b

c

6.SYMPTOM: THE WALKING BELT SLOWS WHEN WALKED ON

a. Use only a UL-listed surge protector, rated at 15 amps, with a 14-gauge cord of five feet or less in length.

b. If the walking belt is overtightened, treadmill performance may

 

decrease and the walking belt may be permanently damaged.

 

Remove the key and

UNPLUG THE POWER CORD

. Using the

allen wrench, turn both rear roller adjustment bolts counterclock-

 

wise, 1/4 of a turn. When the walking belt is correctly tightened,

 

you should be able to lift

the edges

of the walking belt 3 to 4

inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is prop- erly tightened.

b

3–4”

Rear Roller Adjustment Bolts

c. If the walking belt still slows when walked on, please contact our Customer Service Department.

21

Image 21
Contents Customer Information Table of Contents Never move the walking belt while the power Important PrecautionsDo so by an authorized service representa Never insert any object into any openingDecal in the location shown Before You Begin Arrow a while pushing on the Handrail to slide it fully AssemblyScrews Post 101 102Protect the floor or carpet Heart Rate Monitor TROUBLE-SHOOTING HOW to PUT on the Heart Rate MonitorBattery Heart Rate Monitor Care and MaintenanceStore the heart rate monitor in a warm, dry place Erly, the CR 2032 bat- tery may need to beTreadmill Operation Diagram of the Console Features of the ConsoleTo use the Heart Rate program HOW to USE the Manual Mode TIME/PACE display Calories displaySpeed display DISTANCE/INCLINE displaySelect a heart rate setting HOW to USE the Heart Rate ProgramPut on the CardioTrack heart rate monitor Enter your ageBegin walking Heart Rate Monitor Trouble-shootingIncrease If youHOW to USE the Incline Programs Select one of the Incline programs+ button to start the program See on HOW to Select the Information ModeFrom the console INCLINE/DISTANCE HOW to Move the Treadmill HOW to Fold the Treadmill for StorageHold the treadmill firmly with both hands, and lower HOW to Lower the Treadmill for USESymptom the Power does not Turn on Maintenance and Trouble-shootingSymptom the Power Turns OFF During USE Do not operate the treadmill until the problem isUnplug the Power Cord Symptom the Heart Rate Monitor does not Function ProperlySymptom the Walking Belt Slows When Walked on EdgesFactors in a Sensible Diet Conditioning GuidelinesExercise Steps Any exercise programWarm up before you begin Weight Loss TipsToe Touch Stretch Hamstring StretchBenefits of Aerobic Exercise Get FIT with the PowerTreadSession Participate in strength trainingWorkout Tips Workout ProgramsHeart Rate Intensity Key No. Qty Description Black Wire, Male/Female Black Wire, 2 FemaleQty Manufacturer’s One-Year Limited Warranty How to Order Replacement PartsService@nordictrack.com Call us Write usTo identify the parts shown on this Refer toRev B 110 3690 100 104