| Lowest | Highest | Default |
|
Item | Value | Value | Value | Meaning |
|
|
|
|
|
UNx | UNE | UNM | UNE | Units. UNE (English) = units of pounds, miles, feet, inches |
|
|
|
| UNM (Metric) = units of kilograms, kilometers, centimeters |
|
|
|
| NOTE: Current value is shown in PROFILE Window. |
TIM | 5 | 99 | 99 | Time. Maximum time in minutes allowed for a program, excluding cooldown. |
WGT | 1 (lb) | 500 (lb) | 155 (lb) | Default Weight (to user). Typical weight in lb (UNx = UNE) or kg (UNx = |
| 1 (kg) | 226 (kg) | 70 (kg) | UNM). |
Lxx | N/A | N/A | LEN | Language. Display language; either LEN (English), LGE (German), LSP |
|
|
|
| (Spanish), LDU (Dutch), LPO (Portuguese), LFR (French), LIT (Italian), LSW |
|
|
|
| (Swedish) or LKA (Katakana). |
|
|
|
| NOTE: Current value is shown in PROFILE Window. |
LOE | OFF | ON | OFF | Lockout Enable. Enables/disables lockout function. |
LOI | 001 | 999 | 001 | Lockout ID. Lockout override identification number. |
MNS | 0.3 (mi) | 2.0 (mi) | 0.5 (mi) | Minimum Speed. Treadmill minimum operating speed in miles or kilometers, |
| 0.8 (k) | 3.2 (k) | 0.8 (k) | based on current UNx setting. |
MXS | 5.0 (mi) | 12.5 (mi) | 5.0 (mi) | Maximum Speed. Treadmill maximum operating speed in miles or kilometers, |
| 5.0 (k) | 20.0 (k) | 5.0 (k) | based on current UNx setting. |
ACC | 25 | 60 | 25 | Acceleration Time. Time in seconds to accelerate from current speed to a |
|
|
|
| specified higher speed. |
DEC | 20 | 60 | 20 | Deceleration Time. Time in seconds to decelerate from current speed to a |
|
|
|
| specified lower speed. |
AST | OFF | ON | OFF | Auto Stop Enable. Enables/disables Auto Stop function. |
AFE | OFF | ON | OFF | Auto Fan Enable. Enables/disables Auto Fan function. |
PAU | 30 | 120 | 60 | Pause duration during a program, in seconds, either 30, 45, 60, 90 or 120. |
MNP | 4 | 110 | 25 | Minimum PWM. Pulse duty cycle to obtain the selected MN SPD. Divide MN |
|
|
|
| PWM by 512 to get % duty cycle. |
HFP | 50 | 340 | 197 | ½ Maximum PWM. Pulse duty cycle to obtain ½ maximum speed. Divide ½ |
|
|
|
| MX SPD by 512 to get % duty cycle. |
MXP | 172 | 511 | 400 | Maximum PWM. Pulse duty cycle to obtain the selected MX SPD. Divide MX |
|
|
|
| PWM by 512 to get % duty cycle. |
CRV | 31 | 125 | 31 | Counts/Revs. Number of counts for each motor shaft revolution. |
10R | 220 | 740 | 356 | 10 Rev distance in tenths of inches. Inches of running belt travel for 10 |
|
|
|
| flywheel revolutions, always measured in inches. |
PD1 | 1 | 150 | 1 | Person Detect 1. Threshold used for Auto Stop. |
PD2 | 1 | 150 | 1 | Person Detect 2. Threshold used for Auto Stop. |
PD3 | 1 | 150 | 1 | Person Detect 3. Threshold used for Auto Stop. |
NST | 0 | 255 | 0 | No Stop Counter. Number of times No Stop Counter switch was down or |
|
|
|
| disconnected on |
|
|
|
|
|
KYD | 0 | 255 | 0 | Key Down Counter. Number of times key other than 5 or 8 was down on |
|
|
|
| |
SPC | 0 | 255 | 0 | Speed Change Counter. Number of times speed changed suddenly more than 2 |
|
|
|
| mph (UNITS=English) or 2 km/hr (UNITS=Metric) since last reset. |
ELS | 0 | 255 | 0 | Elevation Stall Counter. Number of times elevation failed to change (stalled) |
|
|
|
|
|
46 | STAR TRAC S SERIES TREADMILLS OWNER’S MANUAL |