USING THE RENEW 900
The RENEW 900 is designed for up to four adults.
The six water jets can be regulated to provide a relax- ing massage to sooth away stress, and the strength
of the water massage can be adjusted by the air con- trol. The RENEW 900 holds 300 gallons of water and offers an automatic, programmable heating (70°F to 104°F) and filtration system.
The guidelines below explain how to properly use the
RENEW 900. Follow these guidelines to maintain the
RENEW 900 for your
PRIMING THE SPA JET UNIT
The water pump in the spa jet unit must be primed before you use the RENEW 900 the first time. You must also prime the pump before using the unit each time you
To prime the spa jet unit, remove the primer cap from the console. Fill the spa jet unit with at least 64 oz. of water. Replace and tighten the
primer cap. IMPOR- TANT: The spa jet
unit may be seriously damaged if the pump is not properly primed, or if the primer cap is not replaced and fully tightened.
PLUGGING IN THE RENEW 900
Once the RENEW 900 is filled with enough water to cover the water jets and the pump has been primed, the power cord can be plugged in and the spa jet unit can be turned on. Note: The first time the power cord
is plugged in, the spa jet unit will turn on automatically.
When connecting the power cord, plug the power cord directly into a grounded circuit capable of carrying 15
Grounded circuit capable of carrying 15 or more amps
Test and Reset
Buttons
GFCI
or more amps. No other appliance should be on the
same circuit. Replace the power cord immediately if it becomes damaged.
The power cord is equipped with a Ground Fault
Circuit Interrupter (GFCI), located at the end of the power cord. You should always test the GFCI before using the RENEW 900.
First, turn on the RENEW 900 by pressing the power button on the console. Once the unit is running, press the GFCI “test” button. The RENEW 900 should shut off. Press the “reset” button. The RENEW 900 should resume normal operation. If the RENEW 900 contin-
ues to run after the “test” button is pressed, then the GFCI is damaged. Do not use the RENEW 900 until
the GFCI has been repaired or replaced by a qualified electrician.
STARTING THE RENEW 900
Once you have tested the GFCI, you should verify the water flow from the pumping unit. Set the air control on the console to the lowest setting (see USING THE CONSOLE on the next page). The pumping unit will heat the water as it pumps. Cover the RENEW 900
with the spa cover. The spa cover must be tight. The water will heat at about 1.7°F an hour with the cover on. If you are using the RENEW 900 indoors,
and the room temperature is maintained at 70°F, it will take approximately 20 to 28 hours for the water to reach the set temperature.
The temperature and water flow can be set or changed by the controls on the console (see USING THE CONSOLE on the next page).
TESTING AND TREATING THE WATER
The RENEW 900 comes with a starter chemical pack for maintaining the water in the spa. Disregard the directions on the individual packages of “QUICK pHix It DOWN” and “QUICK pHix It UP.” However, the directions on the bottle of
“Bromine Base” are correct. | Always keep the chemi- |
cals away from children and pets. |
|
The first time you use the spa, you should test and treat the water. Once you have verified that the spa jet unit is functioning properly, and have allowed the water to circulate for a while, you should remove the spa cover and add 1/3 of the “Bromine Base” bottle,
and 1/3 of the
Use the included test strips to check the pH of the
10