USING THE RENEW 900

The RENEW 900 is designed for up to four adults.

The six water jets can be regulated to provide a relax- ing massage to sooth away stress, and the strength

of the water massage can be adjusted by the air con- trol. The RENEW 900 holds 300 gallons of water and offers an automatic, programmable heating (70°F to 104°F) and filtration system.

The guidelines below explain how to properly use the

RENEW 900. Follow these guidelines to maintain the

RENEW 900 for your long-term enjoyment.

PRIMING THE SPA JET UNIT

The water pump in the spa jet unit must be primed before you use the RENEW 900 the first time. You must also prime the pump before using the unit each time you re-fill the RENEW 900.

To prime the spa jet unit, remove the primer cap from the console. Fill the spa jet unit with at least 64 oz. of water. Replace and tighten the

primer cap. IMPOR- TANT: The spa jet

unit may be seriously damaged if the pump is not properly primed, or if the primer cap is not replaced and fully tightened.

PLUGGING IN THE RENEW 900

Once the RENEW 900 is filled with enough water to cover the water jets and the pump has been primed, the power cord can be plugged in and the spa jet unit can be turned on. Note: The first time the power cord

is plugged in, the spa jet unit will turn on automatically.

When connecting the power cord, plug the power cord directly into a grounded circuit capable of carrying 15

Grounded circuit capable of carrying 15 or more amps

Test and Reset

Buttons

GFCI

or more amps. No other appliance should be on the

same circuit. Replace the power cord immediately if it becomes damaged.

The power cord is equipped with a Ground Fault

Circuit Interrupter (GFCI), located at the end of the power cord. You should always test the GFCI before using the RENEW 900.

First, turn on the RENEW 900 by pressing the power button on the console. Once the unit is running, press the GFCI “test” button. The RENEW 900 should shut off. Press the “reset” button. The RENEW 900 should resume normal operation. If the RENEW 900 contin-

ues to run after the “test” button is pressed, then the GFCI is damaged. Do not use the RENEW 900 until

the GFCI has been repaired or replaced by a qualified electrician.

STARTING THE RENEW 900

Once you have tested the GFCI, you should verify the water flow from the pumping unit. Set the air control on the console to the lowest setting (see USING THE CONSOLE on the next page). The pumping unit will heat the water as it pumps. Cover the RENEW 900

with the spa cover. The spa cover must be tight. The water will heat at about 1.7°F an hour with the cover on. If you are using the RENEW 900 indoors,

and the room temperature is maintained at 70°F, it will take approximately 20 to 28 hours for the water to reach the set temperature.

The temperature and water flow can be set or changed by the controls on the console (see USING THE CONSOLE on the next page).

TESTING AND TREATING THE WATER

The RENEW 900 comes with a starter chemical pack for maintaining the water in the spa. Disregard the directions on the individual packages of “QUICK pHix It DOWN” and “QUICK pHix It UP.” However, the directions on the bottle of “Non-chlorine Shox” and

“Bromine Base” are correct.

Always keep the chemi-

cals away from children and pets.

 

The first time you use the spa, you should test and treat the water. Once you have verified that the spa jet unit is functioning properly, and have allowed the water to circulate for a while, you should remove the spa cover and add 1/3 of the “Bromine Base” bottle,

and 1/3 of the “Non-chlorine Shox” bottle to the water in the spa. Allow the water to circulate for five min- utes. You should now test the pH level of the water.

Use the included test strips to check the pH of the

10

Image 10
Contents Customer HOT Line QUESTIONS?Model No Serial No Sears CANADA, INC., TORONTO, Ontario M5B 2B8Table of Contents Use the Renew 900 only as described in this manual Important Safety InstructionsWater pump in the spa jet unit must be Hol or drugs can cause unconsciousness Keep pets away from the Renew 900 at all timesContact a physician Image Before YOU Begin Choosing a Location for the Renew If you set up the Renew 900 insideIf you set up the Renew 900 outside Do not use an extension cord with the RenewFollowing information and instructions AssemblyBefore beginning assembly, carefully read Buckle SlotBuckle Latches and BucklesPriming the SPA JET Unit Using the RenewTesting and Treating the Water Plugging in the RenewLatch Buckle Key Diagram of the Console Using the ConsoleSecuring the SPA Cover JetDraining the Renew SPA JET Unit OperationDraining the Pump Maintenance Symptom the Water does not Heat Symptom the SPA will not OperateSymptom the Pump Hums Symptom the Water Pulsates or There is Minimum Water FlowSymptom the Water Level Drops Symptom the SPA JET Unit ContinuesPower cord must be unplugged Care onOrdering Replacement Parts Model Number of the product Name of the product ImageDate Customer RecordModel No Serial No De l’Industrie St-Jérôme, Québec Canada, J7Y 4B8Limited Five Year Massage SPA Warranty Product Warranty RegistrationDu Modèle De Série References’Achat Garantie Limitée DE Cinq ANS Formulaire DE Garantie DU ProduitPart LIST-Model No Key No. Qty DescriptionR0499A 100430