Gold's Gym GGTL90608.0 Do not fully tighten the Bolts yet, Again. if the Connectors are not CON

Page 8

5.With the help of a second person, carefully tip the treadmill onto its right side. Partially fold the Frame (56) so the treadmill is more stable; do not fully fold the Frame yet.

Attach a Base Pad (81) to the Base (83) in the location shown with a 1" Tek Screw (2) and a Base Pad Spacer (13). Then, attach another Base Pad (81) with only a 1" Tek Screw (2). Remove the 3/8" Nut (8) and the 3/8" x 2" Bolt

(4) from the Base (83). Attach a Wheel (84) with the Bolt and the Nut that you just removed. Do not overtighten the Nut; the Wheel must turn freely.

5

 

83

 

 

2

81

56

 

 

4

 

 

 

 

 

 

 

 

13

 

84

 

2

81

8

 

 

 

 

6. Hold a Bolt Spacer (80) inside the lower end of

6

 

 

 

 

the Left Upright (74). Insert a 3/8" x 4 1/2" Bolt

 

 

 

 

(6) with a 3/8" Star Washer (9) into the Left

 

 

6

 

74

Upright and the Bolt Spacer. Repeat this step

 

 

 

with a second Bolt Spacer (80), 3/8" x 4 1/2"

 

 

9

 

 

Bolt (6), and 3/8" Star Washer (9).

 

 

76

 

Orient the Left Upright (74) and the Left Upright

 

 

 

 

Spacer (76) as shown. Hold the Left Upright

 

80

 

 

 

Spacer and the Left Upright against the Base

 

 

 

 

(83). Partially tighten the two 3/8" x 4 1/2" Bolts

77

80

 

 

 

(6); do not fully tighten the Bolts yet.

83

 

 

Press a Base Endcap (77) into the Base (83).

 

 

 

 

With the help of a second person, tip the tread-

 

 

 

 

 

mill so that the Base (83) is flat on the floor.

 

 

 

 

 

7. Have a second person hold the Bridge (95) near

7

 

 

95

 

the Right Upright (78).

 

 

 

Connect the Upright Wire (38) to the Bridge Wire

 

 

 

 

 

(52). See the inset drawing. The connectors

 

 

 

52

 

should slide together easily and snap into

 

 

 

 

place. If they do not, turn one connector and try

 

 

 

38

 

again. IF THE CONNECTORS ARE NOT CON-

 

 

 

 

78

NECTED PROPERLY, THE CONSOLE MAY

 

 

 

 

BE DAMAGED WHEN THE POWER IS

 

Wire Tie

 

 

TURNED ON. Then, remove the wire tie from the

 

 

 

Upright Wire.

 

 

 

 

52

 

 

 

 

 

38

8

Image 8
Contents QUESTIONS? Model No. GGTL90608.0 Serial NoTable of Contents Important Precautions Pulse sensor is not a medical devicePage Before YOU Begin Assembly Adjustable wrenchMake sure that the power cord is unplugged Do not fully fold the Frame yet1/2 Bolts 6 do not fully tighten Bolts yet Not overtighten the Nut the Wheel must turn FreelyUpright Spacer 79. Be careful not to pinch Again. if the Connectors are not CON Do not fully tighten the Bolts yetBe careful not to pinch the wires Bolts before tightening any of themRaise the Frame 56 to the position shown Oriented as shown and is facing the Console Make sure that no wires are pinchedHold the receiver so that the small cylinder is PRE-LUBRICATED Walking Belt Operation and AdjustmentHOW to Plug in the Power Cord Console Diagram Features of the ConsoleHOW to Turn on the Power HOW to USE the Manual ModeSelect the manual mode Start the walking belt and adjust the speedWhen you are finished exercising, remove Adjust the incline of the treadmill to the lowestFollow your progress with the display Stand onFollow your progress with the display. See on HOW to USE a Personal Trainer WorkoutSelect a personal trainer workout HOW to USE the Ifit Competition Training Center HOW to USE the Settings Mode Select the settings modeMeasure your heart rate if desired. See on Enter user informationInformation Mode Optional Chest Pulse SensorHOW to Fold and Move the Treadmill HOW to Move the TreadmillHOW to Lower the Treadmill for USE Compatible with GFCI-equipped outlets TroubleshootingProblem The power turns off during use Problem The walking belt slows when walked on TopProblem Solution Exercise Guidelines Exercise IntensityWorkout Guidelines Exercise FrequencyPart LIST-Model No. GGTL90608.0 Key No. Qty DescriptionQty Exploded Drawing A-Model No. GGTL90608.0 R1108A 107 105 112 106 Exploded Drawing C-Model No. GGTL90608.0 R1108A Exploded Drawing D-Model No. GGTL90608.0 R1108A Icon Health & Fitness, Inc., 1500 S W., Logan, UT Ordering Replacement PartsLimited Warranty

GGTL90608.0 specifications

Gold's Gym GGTL90608.0 is a comprehensive home fitness solution designed to cater to a wide range of workout preferences, providing versatility and functionality for fitness enthusiasts of all levels. This particular model stands out in the crowded market of home gym equipment due to its combination of innovative technologies and practical features.

One of the main highlights of the Gold's Gym GGTL90608.0 is its adjustable bench design. The bench can easily be repositioned into multiple angles, allowing users to perform a variety of exercises targeting different muscle groups. Whether you're looking to execute flat, incline, or decline presses, the bench's adaptability ensures that you can optimize your workouts for muscle engagement and growth.

The GGTL90608.0 also features a robust weight system, typically equipped with a set of weight plates that can accommodate various strength levels. This adjustability enables users to gradually increase their resistance as they progress in their fitness journey. This progressive overload concept is essential for building strength and improving overall fitness, making the machine suitable for beginners and advanced fitness enthusiasts alike.

Safety is another prominent characteristic of the Gold's Gym GGTL90608.0. The equipment includes safety locks and supports designed to ensure that your workouts are not only effective but also safe. These features are crucial when lifting heavy weights, as they provide peace of mind for users who strive to push their limits.

Another noteworthy aspect is the inclusion of a variety of built-in workout programs. This feature allows users to follow guided workouts tailored to specific goals such as weight loss, muscle building, or overall fitness improvement. The diverse options keep workouts engaging and help users maintain motivation as they strive toward their physical goals.

In terms of construction, the GGTL90608.0 is designed with durability in mind. The sturdy frame is built to withstand rigorous use over time, ensuring that it remains a reliable part of your fitness regimen for years to come. The ergonomic design also contributes to comfort during workouts, an important factor for maintaining proper form and preventing injuries.

Finally, the Gold's Gym GGTL90608.0 benefits from a sleek and compact design, making it suitable for home use without taking up too much space. Its modern aesthetic ensures it can blend seamlessly into your home environment, providing an efficient and functional workout space that can be easily integrated into your daily routine.

Overall, the Gold's Gym GGTL90608.0 is a versatile and reliable home gym solution that combines safety, adaptability, and innovative workout features, making it ideal for anyone looking to enhance their fitness journey from the comfort of their home.