Precor EFX534i t Using Csafe Standard Equipment, User ID Entry Program Keys, Enter Reset

Page 28

C O M M E R C I A L P R O D U C T S D I V I S I O N

Press Enter once again and the Error Log appears. The EFX stores the last ten errors that have been detected. Press any or key to view the error codes.

Note: If the EFX has no errors stored in memory, a “– – –” appears on the display.

To view the odometer reading at the time the error was detected and the hours of use at the time the error occurred, press the Select key while the error code is being displayed. The Select key acts as a toggle between the associated information.

To clear (delete) the error log, press QuickStart for at least four seconds while viewing the list. Prompts appear on the display and confirm (OK) that the error messages have been deleted (“cleared”) from memory.

Important: You cannot retrieve the error log once you have deleted it.

USING CSAFE STANDARD EQUIPMENT

The EFX is fully compatible with CSAFE protocols. Once the unit is connected to a CSAFE master device and the user maintains a stride rate above 40 strides per minute, he or she is prompted to enter an identification number (user ID).

Note: If the optional power adapter is plugged into the EFX and connected to an appropriate power source, then no pedaling is necessary for user ID entry.

Five zeros appear on the display. The left zero indicates that it is awaiting input. The following table provides information about the keypad functions:

User ID Entry:

Program Keys

 

 

or

Enter

Reset

moves the blinking LED from field to field.

submits the displayed user ID. Note that if the five zeros are being displayed when the user presses Enter, the user ID entry is bypassed and the Program prompt appears.

resets the display to the Precor banner.

A message indicates when the user ID is accepted by the CSAFE master device. Then, the program prompt is displayed. See Quick Steps to Working Out on page 39.

Note: If the user’s stride rate drops below 40 strides per minute while using the CSAFE device connection, a prompt PEDAL FASTER appears. If the stride rate remains below the 40 strides per minute threshold for the next twenty seconds, the CSAFE connection is terminated. The word RESETTING appears on the display while the EFX disconnects from the CSAFE device.

To review information about CSAFE specifications, visit the web site at:

www.fitlinxx.com/csafe

Note: The EFX supports the CSAFE master device per the specifications found at the web site. However, exceptions do exist. If you have questions or need technical support, refer to Obtaining Service on page 7.

page 28

Image 28
Contents M M E R C I a L P R O D U C T S D I V I S I O N Important Safety Instructions Diagram 1 Avoid injury from the roller arm mechanism Safety ApprovalHazardous Materials and Proper Disposal Table of Contents Interval Program Changing the Display Features using the Select KeyBack cover RFI Radio Frequency Interference European ApplicationsUser’s authority to operate the equipment European ApplicationsEFX SELF-POWERED Features Obtaining ServiceDiagram 2 EFX serial number location Model number EFX534i Unit number Serial numberAbout this Manual Equipment and prevent injuries to yourselfUnpacking the EFX Standard EquipmentOther Equipment Acquiring the Appropriate ToolsHardware KIT Hardware kitInstallation Requirements Setting Up the EFXAssembly Instructions Diagram Diagram 7 Connect the cables Base tubeDiagram 8 Place the base on supportive blocks Bolts G and washers H Frame stabilizer Diagram 11 Tighten Mounting boltsDiagram 12 Secure Handlebars Protrusions Bracket Tighten bolts securelyM M E R C I a L O D U C T S V I S I O N M M E R C I a L O D U C T S V I S I O N M M E R C I a L O D U C T S V I S I O N Diagram 16 Secure Bracket coverDiagram 17 Level the unit Rotate rear adjustment padsDiagram 18 Clean the ramp Foot pedalDiagram 19 Insert the front end cap Removing the Locking PINDiagram 21 Wearing the chest strap Testing the Heart Rate DisplayDampen with water Custom Settings Mode Changing the Custom SettingsDisplay key functions within the Custom Settings Mode Electrical power must be suppliedDetermining the Units of Measure Setting a Pause Time Limit Setting a Workout Time LimitReset, Enter, QuickStart Using Csafe Standard Equipment Enter ResetUser ID Entry Program Keys Moves the blinking LED from field to fieldFeatures on the Display Console Diagram 23 EFX Display Console SmartRate displayEFX534i Display Center DisplayUser Setup Prompts Setup Prompts DescriptionSelect QuickStartUsing Quickstarttm During the Setup Prompts Weight promptPress Quickstart Following occurs Precor bannerCenter Display Smartrate Display Low BatteryInformational Displays Prior to Shutdown Diagram 24 Display console keypad Keys on the Display ConsoleDefault Values Prompts Default ValueHeart Rate Feature Utilizing the Smartrate FeatureWeight Loss Zone Exercising on the EFXWorkout Tips Using the Handlebars Using the Stationary HandrailChanging the Display Features Using the Select KEY Diagram 26 Using the EFX handlebarsQuick Steps to Working OUT Carefully step down from the EFXPAUSE, Cool Down and Exit Features Cooling Down After a WorkoutA program, This is what happens Is detectedPress Reset Displays the Workout Summary banner Cool down ModeInserting the Locking PIN Pause Mode, youManual Mode and the Quickstarttm KEY ProgramsHill Climb Program Interval ProgramDiagram 27 Target Zones To use the interval program, take the following stepsWeight Loss Program Cross Training ProgramCleaning the Equipment MaintenanceInspection Symptoms of a LOW Battery Using the Power AdapterStoring the Chest Strap Servicing the EFX and Long Term StorageReplacing the Battery Power Adapter Power CordM M E R C I a L P R O D U C T S D I V I S I O N Thank You and Welcome to Precor Date of Purchase Purchased from Dealer name Product Serial NumbersPlease indicate the type and number of products purchased How many members do you have?Limited Warranty Warranty Periods and CoverageConditions and Restrictions Complete this portion and keep for your recordsProduct Specifications Electronic Specifications EFX 534i Programs 5 Total EFX 534i Display Readouts