ProForm PFTL93105.0 user manual Top, Problem The chest pulse sensor does not function properly

Page 23

PROBLEM: The walking belt is off-center or slips when walked on

SOLUTION: a. If the walking belt is off-center, first remove the key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the allen wrench to turn the left rear roller bolt clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the bolt counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b. If the walking belt slips when walked on, first remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller bolts clockwise 1/4 of a turn. When the walking belt is correctly tightened, you should be able to lift each edge of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and walk on the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

PROBLEM: The display of the console does not function properly

SOLUTION: a. Remove the key from the console and UNPLUG THE POWER CORD. Next, remove the screws from the hood and carefully remove the hood. Locate the Reed Switch

(17)and the Magnet (12) on the left side of the Pulley (11). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that the gap between the Magnet and the Reed Switch is about 1/8”. If necessary, move the Reed Switch slightly using a slotted screwdriver. Reattach the hood and run the treadmill for a few minutes to check for a correct speed reading.

a

b

 

a

 

1/8”

 

 

11

17

12

Top

 

View

 

PROBLEM: The chest pulse sensor does not function properly

SOLUTION: a. If the chest pulse sensor does not function properly, see CHEST PULSE SENSOR TROUBLESHOOTING on page 8.

b. If the chest pulse sensor still does not function properly, the battery should be changed. To replace the battery, locate the battery cover on the back of the sensor unit. Insert a coin into the slot in the cover and turn the cover counterclockwise to the “open” position. Remove the cover.

b

Battery Cover

Remove the old battery from the sensor unit. Insert a new CR 2032 battery, making sure that the writing is on top. In addition, make sure that the rubber gasket is in place in the sensor unit. Replace the bat- tery cover and turn it to the closed position.

Battery

Cover

Battery

Rubber

Gasket

23

Image 23
Contents Call TOLL-FREE QUESTIONS?Model No. PFTL93105.0 Serial No Table of Contents Important Precautions Page Right Side Before YOU BeginBack Assembly Tape Chest Pulse Sensor Care and Maintenance HOW to USE the Chest Pulse SensorHOW to PUT on the Chest Pulse Sensor Essary, draining the battery prematurelyPRE-LUBRICATED Walking Belt HOW to Plug in the Power CordTreadmill Operation HOW to Turn on the Power Features of the ConsoleChange the incline of the treadmill as desired HOW to USE the Manual ModeInsert the key into the console Start the walking beltWhen you are finished using the treadmill When you are finished exercising, removeAdjust the incline of the treadmill to the lowest Demo modeSelect a preset program HOW to USE a Preset ProgramFollow your progress with the displays Select a custom program HOW to Create a Custom ProgramHOW to USE a Custom Program Select a heart rate program HOW to USE a Heart Rate ProgramPut on the chest pulse sensor If heart rate program Information MODE/DEMO Mode HOW to Move the Treadmill HOW to Fold and Move the TreadmillHOW to Fold the Treadmill for Storage HOW to Lower the Treadmill for USE Problem The walking belt slows when walked on TroubleshootingProblem The power turns off during use Top Problem The chest pulse sensor does not function properlyExercise Frequency Exercise GuidelinesExercise Intensity Workout GuidelinesSuggested Stretches Qty Description R0106ADescription Exploded DRAWING-Model No. PFTL93105.0 106 119 114 118 101 123 113 121 122 104 116 105 Icon Health & FITNESS, INC., 1500 S W., LOGAN, UT Ordering Replacement PartsLimited Warranty