ProForm 831.297442 user manual Assembly requires a phillips screwdriver not included

Page 5

ASSEMBLY

Assembly requires two people. Set the treadmill in a cleared area and remove the packing materials. Do not dispose of the packing materials until assembly is completed.

Assembly requires a phillips screwdriver (not included).

1.Note: One person must hold the Console Base (91) near the Upright (71) during steps 1, 2, and 3. If this is not done, the wire harness connecting the con- sole to the treadmill may be permanently damaged.

Hold the Console Base (91) near the Upright (71).

Refer to inset drawing A. Connect the Wire Harness (85) to the Console Wire Harness (121). Connect the 4” Ground Wire (120), the 54” Hand Pulse Wire (95) and the 25” Hand Pulse Wire (83) to the Pulse Wire Harness (77) (make sure that the Wires with tags are connected to each other).

2.Slide the Left and Right Base Mounts (104, 78) onto the plastic pins on the sides of the Console Base (91).

Next, carefully insert the Left and Right Base Mounts (104, 78) into the Upright (71) as shown.

Refer to the inset drawing. Carefully feed all wires into the hole in the Upright (71) as shown. Make sure that the wires are routed through the notch in the base mount and under the plastic pin. Be careful not to pull on the wires or they may become disconnected from the console.

3.Slide the Left and Right Lower Base Mounts (105, 79) onto the Left and Right Base Mounts (104, 78). Attach the Lower Base Mounts with eight 3/4” Screws (77) as shown. Be careful not to overtighten the Screws.

1

 

 

91

 

71

A

 

85

121

95

 

83

77

120

 

2

 

104

91

78

 

 

Pin

 

 

 

 

Notch

71

 

 

 

 

 

71

 

 

 

 

3

104

 

78

 

105

 

79

77

 

 

 

77

5

Image 5
Contents Model No Serial No Important Precautions Table of ContentsKeep hands and feet away from Left Right Side Before YOU BeginAssembly requires a phillips screwdriver not included AssemblyGuide is at the bottom HOW to PUT on the Chest Pulse Sensor HOW to USE the Chest Pulse SensorCare and Maintenance Chest Pulse Sensor TROUBLE-SHOOTINGCR 2032 battery may need to be replaced HOW to USE the Hand Pulse SensorBattery Hand Pulse Sensor TROUBLE-SHOOTINGPerformant Lubetm Walking Belt Operation and AdjustmentHOW to Plug in the Power Cord Features of the Console Diagram of the ConsoleHOW to Turn on the Power HOW to USE the Manual Mode CALS./FAT Cals INCLINE/AGEPress the Start button to start the program HOW to USE the Speed ProgramsSelect the desired speed program Select the desired heart rate program HOW to USE the Heart Rate ProgramsSelect the Fitness Test program HOW to USE the Fitness Test ProgramTreadmill is set at 1.5%. Remove the key Page HOW to Create a Custom Program When the program is completed, remove the key HOW to USE a Custom ProgramHOW to Select the Information Mode Press the Start buttonHOW to Fold the Treadmill for Storage HOW to Fold and Move the TreadmillHOW to Adjust the Firmness of the Walking Platform HOW to Lower the Treadmill for USE HOW to Move the TreadmillProblem The walking belt slows when walked on Maintenance and TROUBLE-SHOOTINGProblem The power turns off during use Problem The heart rate monitor does not function properly Workout Guidelines Conditioning GuidelinesExercise Intensity Suggested Stretches Key No. Qty Description R0198AKey No. Qty Description 117 118 114 116 115 65 51 22 6 47 48 108 109 Exploded DRAWING-Model No SEARS, Roebuck and CO., Dept WA, Hoffman ESTATES, IL Full 90 DAY WarrantyModel No