TROUBLESHOOTING
Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please see the front cover of this manual. PROBLEM: The power does not turn on
SOLUTION: a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppressor | ||
is plugged into a properly grounded outlet (see page 12). Use only a | ||
sor that meets all of the specifications described on page 12. IMPORTANT: The treadmill is not | ||
compatible with |
|
|
b. After the power cord has been plugged in, make sure that the key is inserted into the console. | ||
c. Check the reset/off circuit breaker located on the | c |
|
treadmill frame near the power cord. If the switch |
| |
protrudes as shown, the circuit breaker has tripped. |
|
|
To reset the circuit breaker, wait for five minutes | Tripped | Reset |
and then press the switch back in. | ||
PROBLEM: The power turns off during use |
|
|
SOLUTION: a. Check the reset/off circuit breaker (see the drawing above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.
b.Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for five minutes, and then plug it back in.
c.Remove the key from the console. Reinsert the key into the console.
d.If the treadmill still will not run, please see the front cover of this manual.
PROBLEM: The incline of the treadmill does not change correctly
SOLUTION: a. Hold down the Stop button and the Speed increase button, insert the key into the console, and | ||
then release the Stop button and the Speed increase button. Press the Incline increase or de- | ||
crease button. The treadmill will automatically rise to the maximum incline level and then return to | ||
the minimum level. This will recalibrate the incline system. If the incline does not calibrate, press | ||
the Stop button, and then press the Incline increase or decrease button again. When the incline | ||
is calibrated, remove the key from the console. |
|
|
PROBLEM: The displays of the console do not function properly |
|
|
SOLUTION: a. Remove the key from the console and UNPLUG | a | 74 |
THE POWER CORD. With the help of a second | ||
person, carefully tip the Uprights (74, 78) down. |
|
|
There may be two #8 x 2" Screws (105) in the bot- |
|
|
tom of the Belly Pan (73). If there are, remove |
|
|
them. Note: A Phillips screwdriver with a shaft at | 78 | 73 |
least 5 in. (13 cm) long is required. Then, raise the | ||
Uprights. |
| 105 |
|
| |
|
| 105 |
22 |
|
|