Seiko 7K32 manual Pull our crown 1 to the sec- ond click

Page 30

[Method 1: To set the 24-hour hand to the current time of your area]

(1)Pull out crown “1” all the way to the second click. Notes:

Pull out the crown to the second click when the small second hand is at the 12 o'clock. The small second hand stops on the spot.

The alarm hands stop, indicating the time when crown “1” is pulled out.

The two barometer hands move to indicate “1000hPa” and “0hPa”, respectively. Atmospheric pressure measurement is not made while the crown “1” is at the second click position.

Make sure that crown “2” is at the normal or first click position.

(2)Turn crown “1” clockwise to set the 24-hour and minute hands to the current time of your area.

Notes:

The date may change depending on the time that the hour hand indicates. It is not necessary to reset them at this step, as they can be adjusted independently later.

When setting the minute hand, advance it 4 to 5 minutes ahead of the desired time and then turn it back to the exact time.

(4)Set the hour hand to the current hour. To do so, first pull out crown “2” to the second click. Notes:

The alarm hands keep indicating the set time.

Do not press button C as this will move the alarm hands.

(5)Turn crown “2” counterclockwise to set the hour hand to the current hour.

Notes:

Check that AM/PM is correctly set by turning the hour hand past the 12 o'clock marker. If the date changes to the next, the time is set for the AM period. If the date does not change, the time is set for PM period.

The hour hand moves in 1-hour increments.

(6) After setting the hour hand, push crown “2” back in to the normal position.

The time setting procedure for “Method 1” has been completed. This use is very convenient when you travel abroad. The 24-hour hand shows the time back home, while the time of the place you visit can be shown by adjusting the hour hand independently of the 24-hour hand

Set the alarm hands to the current time and adjust the barometer hand position.

Refer to “Alarm hand setting”.

Refer to “Barometer hand position adjustment”.

(3) Push crown “1” back in to the normal position in accordance

00 1

0

 

 

m

 

 

0

 

0

5

0

 

 

95

 

0

 

9

0

 

 

 

24

0 1000

9 0 1

82

73

6 5 4

A

 

 

 

 

L

 

 

 

 

T

 

 

 

 

I.

 

10

 

 

5

50

 

5

 

hP

 

0

 

 

a

 

0

 

 

 

5

5

 

 

 

0

 

 

 

0

 

 

 

 

0

 

 

 

 

0

 

 

 

 

0

each time you move to a different time zone. (Refer to “Time difference adjustment”.)

[Method 2: To set the 24-hour hand to the time of an area in a different time zone]

(1) Pull out crown “1” all the way to the second click.

Notes:

with a time signal.

Adjustments of the 24-hour, minute and small second hands

have been completed. Notes:

As the crown “1” is pushed back in to the normal position, the barometer hands indicate the current atmospheric pressure.

The alarm hands start moving in 1-minute increments correspondingly with the small second hand.

 

0

18

0

5

8

 

0

 

 

5

 

 

1

8

 

0

 

0

0

 

0

 

0

 

2

 

 

L A N D

 

5

 

6

 

 

5

 

 

 

M A S T E R

 

0

 

 

 

TITANIUM

 

 

 

12

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

9

 

3

 

6

0

0

 

ALARM

 

 

0

7

6

 

0

 

50

70

0

65

3

 

 

 

 

 

 

 

 

5

 

 

005

 

3

0

 

 

 

0

 

 

 

2

000

 

 

 

 

 

4

 

5

 

0

 

0

0

4

Pull our crown “1” to the sec- ond click.

Pull out the crown to the second click when the small second hand is at the 12 o'clock. The

small second hand stops on the spot.

The alarm hands stop, indicating the time when crown “1” is pulled out.

The two barometer hands move to indicate “1000hPa” and “0hPa”, respectively. Atmospheric

pressure measurement is not made while the crown “1” is at the second click position.

Make sure that crown “2” is at the normal or first click position.

53

54

Image 30
Contents ランドマスター サミッター 取扱いを誤った場合に、重傷を負うなどの重大な結果になる危険性が想定されることを示します。 取扱いを誤った場合に、軽傷を負う危険性や物質的損害をこうむることが想定されることを示し ます。ご使用前に必ずお読みいただきたいこと…………………………………… 電池交換後のお願い(システムリセット)とご注意………………………34ご使用前に必ずお読みいただきたいこと 操作概略 製品の特長各部の名称とはたらき 時刻の合わせかた(基本時計・アラーム小時計の時刻・気圧針の0位置合わせ)気圧傾向針 ・たとえば、日本時間に合わせておくと、海外 旅行のときに旅先の時刻を時分針で表示して 小秒針 リュウズ1 ④時針を現在時刻に合わせます。リュウズ2を2段目まで引き出してください。 アラーム小時計の時刻の合わせかた 気圧針の0位置合わせ せます。ボタンAを押し続けると早く進みます。を2段目 日付けの合わせかた を1段目ボタンB 時差修正の使いかた(1時間単位の時差) リュウズ2 を2段目③修正が済みましたらリュウズ2を押し込んでください。 都市と時差の比較表 アラームの使いかた(12時間制で1分単位のアラームセット)アラームON a リュウズ2 (1段目) リュウズ2通常位置 (0段目)デイリーアラームOFF リュウズ2 (1段目)リュウズ2 気圧計の使いかた 〈気圧値の読みかた〉の間のやや左側 0段目 ボタンCリュウズ1は 最低気圧値からその外側の簡易高度目盛りを読むと簡易的に最高高度が分かります。9秒位置 6秒位置 回転ベゼルの使いかた気圧計測に関する注意事項 〈簡易高度の読み取りかた〉気圧の上昇傾向大 → 天気の回復傾向大 天気の回復傾向小 気圧傾向針の使いかた→ 通常の気圧変化を越える気圧上昇があった時 気圧変化ほとんどなし → 今の天気が続くデモンストレーションについて(気圧関係の針とアラーム小時計) ③血液型 Rh+AB型の人 ④生年月日(3)電池交換 電池についてのお願いとご注意.電池について (1)電池寿命 この時計は、新しい正常な電池を組み込んだ場合、その後約2年作動します。 電池交換は必ずお買い上げ店、またはセイコー取扱店で「セイコー純正SB電池」とご指定の上、 ご用命ください。「ルミブライト」について 日常のお手入れ静電気について かぶれやアレルギーについて保管について 磁気についてその他、携帯上ご注意いただきたいこと こんな時には バンドの長さを簡単に調整する機構です。衣類の上に着用する際などにお役立て下さい。 ③上蓋製品仕様 アフターサービスについて補修用性能部品について Page Features Be Sure to Observe the FollowingDisplay and Crown Operation Pull our crown 1 to the sec- ond click Page HOW to SET the Alarm Hands Pull out crown 1 all the way to the secondPull out crown 1 to the second click Barometer Hand Position Adjustment Oclock positionHOW to SET the Date Time Difference AdjustmentTime Differences Pull out crown 2 to the second clickKeep crown 2 at the normal position Single-time alarmConvenient, for example, for reminding you Set crown 2 atWith each press of button A, the alarm Hour hand advances one hour. It advances a〈Examples〉 Time difference HOW to USE the BarometerNumber of hours to advance Alarm hour hand Barometer hand 2 indicates 1013hPaBarometer hand 2 indicates Button B Ex hPa/Approxi- mately 1,000m Know the approximate altitudeHOW to USE the Rotating Bezel (1)(2) Remarks on Using the Barometer Function Second position Barometer handWeather is very likely to improve → The atmospheric pressure has risen unusuallyAtmospheric pressure is rising greatly Atmospheric pressure is rising slightlyRemarks on the Battery Demonstration Movement of the Barometer and Alarm HandsPersonal Data To Preserve the Quality of Your Watch Rash and Allergy Lumibrite Periodic CheckTrouble Shooting Phenomenon Possible causeWhen having them repair your watch Originals are not availableSpecifications