Weider WESY75742 user manual Troubleshooting, Recalibrating the Console, Cleaning the BAR Guides

Page 19

TROUBLESHOOTING

RECALIBRATING THE CONSOLE

To recalibrate the Console (67), first plug in the resist- ance system (see PLUGGING IN THE RESISTANCE SYSTEM on page 16). Then, press and hold the NEXT button and the MOTORIZED WEIGHT ADJUSTMENT + button for five seconds. When the buttons are released, a number will appear in the REPS display. Press the NEXT button again, then press the MOTORIZED WEIGHT ADJUSTMENT + button; this will start the recalibration process. This may take a few minutes as the motor moves between the lowest and highest resistance settings. When the motor finishes, unplug the transformer from the 120- volt outlet.

The Console (67) will be recalibrated. Use the resist- ance system as described in the CONSOLE OPERA- TION section, starting on page 16.

CLEANING THE BAR GUIDES

Over time, dust may build up on the Crossbar Guides (15), causing a squeaking noise as the resistance system is used. If this occurs, wipe off the Crossbar Guides with a damp cloth and a mild, non-abrasive detergent. Do not use solvents.

ADJUSTING THE RESISTANCE

When the resistance setting changes, the motor will be heard. To prevent damage to the motor, do not pull any of the cables while the resistance setting is changing. If a cable is pulled, the words

RELEASE HANDLES AND READJUST RESIST- ANCE AS DESIRED may appear in the main display on the console.

If this message is displayed repeatedly but no cable is being pulled, there may be too much tension on the upper cable (A). Adjust the tension as described below.

To decrease the tension on the upper cable (A), turn the two 3/8” x 38mm Tension Screws (114) twice, counterclockwise. Select the desired resistance set- ting. Repeat this step if necessary.

67

 

15

 

A

114

19

 

Image 19
Contents Model No. WESY75742 Serial No QUESTIONS?Table of Contents Keep hands and fingers clear of this area Important Precautions Before YOU Begin Make Things Easier for Yourself AssemblyTighten all parts as you assemble them, unless Tighten the 1/2 x 25mm Screw Is Turned on Push the excess Upper Wire Harness 71 intoUpright Sure that the Upper Cable 121 is between Two Pulleys Do not tighten the Locknut yetDo not tighten the Bolt yet Make sure the hexagonal hole in the Screw is That the Cable is routed as shown Cable Diagram onOn the outside of the Bracket Described in Console Operation on Inset drawingUpper Cable Adjustment Using the LEG Lever AdjustmentsEnted as shown when attaching it to the Leg Adjusting the Backrest Adjusting the Squat ARMAttaching the Squat Station Adjusting the Seat Attaching the AccessoriesStoring the Resistance System Manual Operation Features of the Console Console Operation Plugging in the Resistance SystemProgram Operation Upper Cable Cable DiagramRecalibrating the Console TroubleshootingCleaning the BAR Guides Adjusting the ResistanceExercise Form Exercise GuidelinesWarming UP Working OUTCooling Down Muscle ChartStaying Motivated Aerobic Exercise Exercise Weight Sets RepsWeight Sets Reps Thursday Aerobic Exercise DateMonday Key No. Qty Description Key No. QtyPart Identification CHART-Model No. WESY75742 Exploded DRAWING-Model No. WESY75742 Limited Warranty Ordering Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT