Whirlpool W10057363B Attach long hose to Y connector and tighten couplings, Check for leaks

Page 16

3. Tighten couplings

A

Using pliers, tighten the couplings with additional two-thirds turn.

NOTE: Do not overtighten. Damage to the coupling can result.

4. Attach long hose to “Y” connector and tighten couplings

One end of the long hose has a

wire mesh strainer inside the coupling. Attach this end to the “Y” connector. Attach washer cold inlet hose to other side of “Y” connector. Screw on coupling by hand until it is seated on connector. Using pliers, tighten the couplings an additional two-thirds turn.

NOTE: Do not overtighten. Damage to the coupling can result.

5. Attach long hose to dryer fill valve and tighten coupling

Remove protective cap from water inlet valve. Attach other end

of long hose to fill valve at bottom of dryer

back panel. Screw on coupling by hand until it is seated on fill valve connector. Using pliers, tighten the couplings an additional two-thirds turn.

NOTE: Do not overtighten. Damage to the coupling can result.

6. Turn on cold water faucet

Check that the water faucets are turned on.

7. Check for leaks

Check for leaks around “Y” connector, faucet, and hoses.

16

Image 16
Contents Electric Dryer Installation Instructions Dryer Safety Installation Requirements If using a power supply cordTools needed Parts suppliedInstallation Clearances Location RequirementsElectrical Requirements Install Leveling Legs If connecting by direct wirePrepare dryer for leveling legs Screw in leveling legsFor power supply cord installations Electric InstallationFor direct wire installations Power Supply Cord Connection Attach power supply cordPrepare to connect neutral ground wire and neutral wire Connect neutral ground wire and neutral wireConnect ground wire Connect remaining wiresConnect neutral wire Remove center screwDirect Wire Connection Direct wire strain relief Attach direct wire strain reliefAttach direct wire cable to strain relief Wire Direct Wire ConnectionPrepare your 3-wire cable for direct connection Wire Direct Wire ConnectionConnect external ground wire Optional External Ground for 3-Wire ConnectionPower Supply Cord Shown Venting Venting Requirements Special provisions for mobile homes Plan Vent SystemDetermine vent path Install Vent System Connect Inlet HoseAttach long hose to Y connector and tighten couplings Attach long hose to dryer fill valve and tighten couplingTurn on cold water faucet Check for leaksConnect vent Level dryerComplete Installation ChecklistDoor Reversal optional Move the door strikeRemove door from dryer Remove inner door from outer doorRemove outer window assembly from trim ring Reverse outer window assemblyReinstall hinge and latch on opposite sides Rotate and reassemble outer window assembly to trim ringRemove hinge and latch Reinstall inner door assembly Reinstall door on dryerPage 2010 11/10 All rights reserved