Whirlpool W10057363B Optional External Ground for 3-Wire Connection, Connect external ground wire

Page 12

4. Connect remaining wires

Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

Optional External Ground for 3-Wire Connection

(Power Supply Cord Shown)

IMPORTANT: You must verify with a qualified electrician that this grounding method is acceptable before connecting.

1. Prepare to connect neutral ground wire and neutral wire

E

B

A

Install the correct strain relief for your electrical connection method, as shown on page 8 or 10.

Remove center terminal block screw (B). Remove neutral ground wire (E) from green external ground conductor screw (A).

2. Connect neutral ground wire and neutral wire

B

E

C

Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center, terminal block screw (B). Tighten screw.

3. Connect remaining wires

Place ends of remaining wires under outer terminal block screws. Tighten screws.

4. Connect external ground wire

A

G

Connect a separate copper ground wire (G) under the green external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements.

12

Image 12
Contents Electric Dryer Installation Instructions Dryer Safety Installation Requirements If using a power supply cordTools needed Parts suppliedInstallation Clearances Location RequirementsElectrical Requirements Install Leveling Legs If connecting by direct wirePrepare dryer for leveling legs Screw in leveling legsElectric Installation For power supply cord installationsFor direct wire installations Power Supply Cord Connection Attach power supply cordPrepare to connect neutral ground wire and neutral wire Connect neutral ground wire and neutral wireConnect ground wire Connect remaining wiresConnect neutral wire Remove center screwDirect Wire Connection Direct wire strain relief Attach direct wire strain reliefAttach direct wire cable to strain relief Wire Direct Wire ConnectionPrepare your 3-wire cable for direct connection Wire Direct Wire ConnectionOptional External Ground for 3-Wire Connection Connect external ground wirePower Supply Cord Shown Venting Venting Requirements Plan Vent System Special provisions for mobile homesDetermine vent path Install Vent System Connect Inlet HoseAttach long hose to Y connector and tighten couplings Attach long hose to dryer fill valve and tighten couplingTurn on cold water faucet Check for leaksConnect vent Level dryerComplete Installation ChecklistDoor Reversal optional Move the door strikeRemove door from dryer Remove inner door from outer doorRemove outer window assembly from trim ring Reverse outer window assemblyRotate and reassemble outer window assembly to trim ring Reinstall hinge and latch on opposite sidesRemove hinge and latch Reinstall inner door assembly Reinstall door on dryerPage 2010 11/10 All rights reserved