Plan Vent System
Choose your exhaust installation type
Recommended exhaust installation:
B C
A D
F E G
B
H
A. | Dryer | F. | Rigid metal or | |
B | Elbow |
| flexible metal vent | |
C. | Wall | G. | Vent length | |
D. | Exhaust hood |
| necessary to | |
E. | Clamps |
| connect elbows | |
H. | Exhaust outlet | |||
|
|
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. Terminate exhaust vent outside.
Determine vent path:
■■Select route that will provide straightest and most direct path outdoors.
■■Plan installation to use fewest number of elbows and turns.
■■When using elbows or making turns, allow as much room as possible.
■■Bend vent gradually to avoid kinking. ■■Use as few 90° turns as possible.
Determine vent length and elbows needed for best drying performance:
■■Use the following Vent System Chart to determine type of vent material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in Vent system chart.
Exhaust systems longer than those specified will: ■■Shorten life of dryer.
■■Reduce performance, resulting in longer drying times and increased energy usage.
The Vent System Chart provides venting requirements that will help achieve best drying performance.
Vent System Chart
| Number of | Type | Box/louvered | Angled |
|
| 90° elbows | of vent | hoods | hoods |
|
|
|
|
|
|
|
| 0 | Rigid metal | 64 ft. (20 m) | 58 ft. (17.7 m) |
|
|
|
|
|
|
|
| 1 | Rigid metal | 54 ft. (16.5 m) | 48 ft. (14.6 m) |
|
|
|
|
|
|
|
| 2 | Rigid metal | 44 ft. (13.4 m) | 38 ft. (11.6 m) |
|
|
|
|
|
|
|
| 3 | Rigid metal | 35 ft. (10.7 m) | 29 ft. (8.8 m) |
|
|
|
|
|
|
|
| 4 | Rigid metal | 27 ft. (8.2 m) | 21 ft. (6.4 m) |
|
|
|
|
|
|
|
|
|
|
|
|
|
14