Removal of transport bracket

The washing machine is fitted with a transport bracket to avoid any possible damage during transport.

IMPORTANT: Before using the washing machine, the transport bracket at the back MUST be removed.

1.Unscrew the two screws “A” and the four screws “B” with a flat screwdriver or a No. 8 hex nut box spanner.

2.Remove the transport bracket.

3.Replace the four outer screws “B” on the machine and tighten them.

4.Clip the two seals “C” supplied into the openings “D” of the washing machine.

Note: do not forget to replace and tighten the four outer screws.

AB

D

1

1

1

2

C

4 D

4

GB 16

Image 16
Contents Contents Install the washing machine Remove the packaging and checkRemove the transport bracket Water supplySafety instructions EC Declaration of Conformity PackingDisposing of packaging and old washing machines Energy saving tipsDescription of the Washing Machine Adjustable feetBefore the First Wash Cycle Preparation of the Washing Sort the laundryStain removal Dyeing and bleachingLoading the laundry Detergents and Additives Choice of the right detergents and additivesDosage Do not use solvents turpentine, benzine, etcUsing chlorine bleach Where to put detergents and additivesUsing starch powder Cleaning the FILTER/ Draining Residual Water Water inlet hose filter Detergent dispenserWater inlet hose Appliance exterior and control panel Appliance interiorLid seal Water inlet hosesTroubleshooting Guide Description of red indications Red indication lamp Indication on Description AFTER-SALES Service Before contacting After-Sales ServiceTransport and Handling SpecifyInstallation Removal of transport bracketAdjust the feet Connect the water inlet hoseWater stop anti-flooding system Connect the water drain hoseIs the risk of leakage and of scalding with hot water Fix the U bend C at the very end of the drain hoseTo fit a new plug, proceed as follows Brown Live LPolarized Plugs e.g pin, 13 amp plug conforming to BS 1363A