3-Wire Direct Wire Connection

IMPORTANT: Use where local codes permit connecting cabinet-ground conductor to neutral wire.

1. Prepare your 3-wire cable for direct connection

 

1"

 

(25

mm)

 

 

3½"

 

(89

mm)

 

 

 

Direct wire cable must have 5 ft. (1.52 m) of extra length so washer/dryer may be moved

if needed.

Strip 31/2" (89 mm) of outer covering from

end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare

wire even with outer covering. Shape wire ends into hooks.

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw

2. Connect neutral wire

A

D

Remove center terminal block screw (A). Place the hooked end of the neutral wire (D) (white or center wire) of direct wire cable under the center screw of terminal block (A) (hook facing right). Squeeze hooked end together. Tighten screw

3. Connect other wires

Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

4.Tighten strain relief screw.

5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

6.You have completed your electrical connection. Now go to “Venting Requirements.”

Optional 3-Wire Connection

IMPORTANT: You must verify with a qualified electrician that this grounding method is acceptable before connecting.

1. Connect neutral ground wire and neutral wire

D

B

C

Remove center terminal block screw. Remove neutral ground wire (B) from external ground conductor screw (C). Connect neutral ground wire (B) and the neutral wire (D) (white or center wire) of power supply cord/cable under center, terminal block screw. Tighten screw.

2. Connect other wires

Connect the other wires to outer terminal block screws. Tighten screws.

3.Tighten strain relief screws.

4.Connect a separate copper ground wire from the external ground conductor screw to an adequate ground.

5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

14

Image 14
Contents WASHER/DRYER Safety Table of ContentsWASHER/DRYER Safety Parts supplied Installation RequirementsTools needed Optional tools If you have You will need Mobile home installations require Recessed area or closet installationMobile Home Additional Installation Requirements Location RequirementsClearances DIMENSIONS/CLEARANCESDimensions Front View Side View Back ViewWall standpipe drain system Drain SystemFloor standpipe drain system Floor drain systemElectrical Connection Electrical RequirementsIt is your responsibility Open washer lid and pull out foam packing ring Install rear leveling legsInstall front leveling legs Remove terminal block cover Electrical ConnectionChoose electrical connection type Connect neutral ground wire and neutral wire Power Supply Cord ConnectionAttach power supply cord Connect ground wireConnect neutral wire Direct Wire ConnectionDirect Wire Strain Relief Attach direct wire strain relief Attach direct wire cable to strain reliefConnect other wires Wire Direct Wire ConnectionPrepare your 4-wire cable for direct connection Prepare your 3-wire cable for direct connection Optional 3-Wire ConnectionVenting Venting RequirementsAlternate installations for close clearances Recommended exhaust installationsOptional exhaust installations Plan Vent SystemSpecial provisions for mobile home installations Install Vent SystemInstall exhaust hood Connect vent to exhaust hoodConnect Drain Hose Attach drain hose to drain connectorRemove drain hose form floor drain installations only Attach clamp to drain hoseConnect Inlet Hoses Secure drain hose Connect Inlet Hoses Connect VentCheck for leaks Connect vent to exhaust outlet Laundry Tub Standpipe WallCheck levelness of washer/dryer Adjust leveling legsLevel WASHER/DRYER Plug into a grounded 3- or 4-prong outletComplete Installation Checklist If the dryer will not start, check the followingPage TM 2013 Whirlpool. All rights reserved