Whirlpool W10558490A installation instructions Connect Inlet Hoses

Page 19

CONNECT INLET HOSES

Washer must be connected to water faucets with new inlet hoses with flat washers. Do not use old hoses.

NOTE: Both hoses must be attached and have water flowing to inlet valves. If you are only connecting to a cold water faucet, you must use a Y-adapter (not included).

1. Insert washer into each hose

WasherCoupling

Insert a new flat washer into each end of the inlet hoses. Firmly seat the washers in the couplings.

2. Connect inlet hoses to water faucets

Attach hose to hot water faucet. Screw on coupling by hand until it is seated on washer. Use pliers to tighten couplings an additional two-thirds turn. Repeat this step with second hose for cold water faucet.

IMPORTANT: Do not overtighten or use tape or sealants on valve when attaching to faucets or washer. Damage can result.

HELPFUL TIP: Make note of which hose is connected to hot water to help in attaching hoses to washer correctly. In most standard configurations, hoses will cross over each other when attached correctly.

3. Clear water lines

Run water for a few seconds through hoses into a laundry tub, drainpipe, or bucket to prevent clogs. Water should run until clear.

4. Connect inlet hoses to washer

Attach hot water hose to the bottom inlet valve. Screw coupling by hand until it is snug. Use pliers to tighten couplings an additional two-thirds turn. Repeat with cold water inlet valve (top valve).

IMPORTANT: To reduce risk of hose failure, replace the hoses every 5 years. Record hose installation or replacement dates for future reference.

nPeriodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found.

5.Move washer/dryer to final location

If you are working in a closet or recessed area: move the washer/dryer into its final location and remove cardboard from under washer/dryer. Remove the access panel by removing 3 Phillips-head screws and one bumper, located at the top of the access panel. Set panel, screws, and bumper aside. Complete hookup of water hoses and vent. Replace access panel upon completion of washer/dryer installation.

19

Image 19
Contents Table of Contents WASHER/DRYER SafetyWASHER/DRYER Safety Tools needed Optional tools Installation RequirementsParts supplied If you have You will need Location Requirements Recessed area or closet installationMobile Home Additional Installation Requirements Mobile home installations requireFront View Side View Back View DIMENSIONS/CLEARANCESDimensions ClearancesFloor drain system Drain SystemFloor standpipe drain system Wall standpipe drain systemIt is your responsibility Electrical RequirementsElectrical Connection Install front leveling legs Install rear leveling legsOpen washer lid and pull out foam packing ring Choose electrical connection type Electrical ConnectionRemove terminal block cover Connect ground wire Power Supply Cord ConnectionAttach power supply cord Connect neutral ground wire and neutral wireAttach direct wire cable to strain relief Direct Wire ConnectionDirect Wire Strain Relief Attach direct wire strain relief Connect neutral wirePrepare your 4-wire cable for direct connection Wire Direct Wire ConnectionConnect other wires Optional 3-Wire Connection Prepare your 3-wire cable for direct connectionVenting Requirements VentingPlan Vent System Recommended exhaust installationsOptional exhaust installations Alternate installations for close clearancesConnect vent to exhaust hood Install Vent SystemInstall exhaust hood Special provisions for mobile home installationsAttach clamp to drain hose Attach drain hose to drain connectorRemove drain hose form floor drain installations only Connect Drain HoseConnect Inlet Hoses Laundry Tub Standpipe Wall Connect Inlet Hoses Connect VentCheck for leaks Connect vent to exhaust outlet Secure drain hosePlug into a grounded 3- or 4-prong outlet Adjust leveling legsLevel WASHER/DRYER Check levelness of washer/dryerIf the dryer will not start, check the following Complete Installation ChecklistPage TM 2013 Whirlpool. All rights reserved