Whirlpool W10558490A installation instructions Venting Requirements

Page 15

VENTING

Venting Requirements

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

Dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic, crawlspace, or a concealed space of a building. Only rigid or flexible metal vent shall be used for exhausting.

4"

(102 mm)

4" (102 mm) heavy metal exhaust vent

■■Only a 4" (102 mm) heavy metal exhaust vent and clamps may be used.

■■Do not use plastic or metal foil vent.

Rigid metal vent:

■■Recommended for best drying performance and to avoid crushing and kinking.

Flexible metal vent: (Acceptable only if accessible to clean) ■■Must be fully extended and supported in final dryer location.

■■Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance.

■■Do not install in enclosed walls, ceilings, or floors. ■■The total length should not exceed 73/4 ft. (2.4 m).

NOTE: If using an existing vent system, clean lint from entire length of the system and make sure exhaust hood is not plugged with lint. Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review “Vent System Chart” and, if necessary, modify existing vent system to achieve best drying performance.

Exhaust hoods:

■■Must be at least 12" (305 mm) from ground or any object that may obstruct exhaust (such as flowers, rocks, bushes, or snow).

Recommended Styles:

Louvered hood

Box hood

Acceptable Style:

Angled hood

Elbows:

■■45° elbows provide better airflow than 90° elbows.

Good Better

Clamps:

■■Use clamps to seal all joints.

■■Exhaust vent must not be connected or secured with screws or other fastening devices that extend into interior of duct and catch lint. Do not use duct tape.

See “Venting Kits” for more information.

15

Image 15
Contents Table of Contents WASHER/DRYER SafetyWASHER/DRYER Safety Installation Requirements Tools needed Optional toolsParts supplied If you have You will need Location Requirements Recessed area or closet installationMobile Home Additional Installation Requirements Mobile home installations requireFront View Side View Back View DIMENSIONS/CLEARANCESDimensions ClearancesFloor drain system Drain SystemFloor standpipe drain system Wall standpipe drain systemElectrical Requirements It is your responsibilityElectrical Connection Install rear leveling legs Install front leveling legsOpen washer lid and pull out foam packing ring Electrical Connection Choose electrical connection typeRemove terminal block cover Connect ground wire Power Supply Cord ConnectionAttach power supply cord Connect neutral ground wire and neutral wireAttach direct wire cable to strain relief Direct Wire ConnectionDirect Wire Strain Relief Attach direct wire strain relief Connect neutral wireWire Direct Wire Connection Prepare your 4-wire cable for direct connectionConnect other wires Optional 3-Wire Connection Prepare your 3-wire cable for direct connectionVenting Requirements VentingPlan Vent System Recommended exhaust installationsOptional exhaust installations Alternate installations for close clearancesConnect vent to exhaust hood Install Vent SystemInstall exhaust hood Special provisions for mobile home installationsAttach clamp to drain hose Attach drain hose to drain connectorRemove drain hose form floor drain installations only Connect Drain HoseConnect Inlet Hoses Laundry Tub Standpipe Wall Connect Inlet Hoses Connect VentCheck for leaks Connect vent to exhaust outlet Secure drain hosePlug into a grounded 3- or 4-prong outlet Adjust leveling legsLevel WASHER/DRYER Check levelness of washer/dryerIf the dryer will not start, check the following Complete Installation ChecklistPage TM 2013 Whirlpool. All rights reserved