Whirlpool W10558490A Install Vent System, Install exhaust hood, Connect vent to exhaust hood

Page 17

Special provisions for mobile home installations:

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path:

■■Select route that will provide straightest and most direct path outdoors.

■■ Plan installation to use fewest number of elbows and turns.

■■ When using elbows or making turns, allow as much room as possible.

■■ Bend vent gradually to avoid kinking. ■■ Use as few 90° turns as possible.

Determine vent length and elbows needed for best drying performance:

■■Use following “Vent System Chart” to determine type of vent material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified

in “Vent System Chart.” Exhaust systems longer than those specified will:

■■Shorten life of dryer.

■■Reduce performance, resulting in longer drying times and increased energy usage.

The “Vent System Chart” provides venting requirements that will help achieve best drying performance.

Vent System Chart

Number of

Type

Box/louvered

Angled

90° turns

of vent

hoods

hoods

or elbows

 

 

 

0

Rigid metal

43 ft. (13.1 m)

36 ft. (11.0 m)

 

 

 

 

1

Rigid metal

33 ft. (10.1 m)

26 ft. (7.9 m)

 

 

 

 

2

Rigid metal

24 ft. (7.3 m)

16 ft. (4.9 m)

 

 

 

 

NOTE: Side exhaust installations have a 90º turn inside the dryer. To determine maximum exhaust length, add one 90º turn to the chart.

INSTALL VENT SYSTEM

1. Install exhaust hood

12" min.

(305 mm)

12" min. (305 mm)

Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood.

2. Connect vent to exhaust hood

Vent must fit over the exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp. Run vent to dryer location using straightest path possible. Avoid 90° turns. Use clamps to seal all joints. Do not use duct tape, screws, or other fastening devices that extend into interior of vent to secure vent, because they can catch lint.

17

Image 17
Contents Table of Contents WASHER/DRYER SafetyWASHER/DRYER Safety Parts supplied Installation RequirementsTools needed Optional tools If you have You will need Mobile Home Additional Installation Requirements Recessed area or closet installationMobile home installations require Location RequirementsDimensions DIMENSIONS/CLEARANCESClearances Front View Side View Back ViewFloor standpipe drain system Drain SystemWall standpipe drain system Floor drain systemElectrical Connection Electrical RequirementsIt is your responsibility Open washer lid and pull out foam packing ring Install rear leveling legsInstall front leveling legs Remove terminal block cover Electrical ConnectionChoose electrical connection type Attach power supply cord Power Supply Cord ConnectionConnect neutral ground wire and neutral wire Connect ground wireDirect Wire Strain Relief Attach direct wire strain relief Direct Wire ConnectionConnect neutral wire Attach direct wire cable to strain reliefConnect other wires Wire Direct Wire ConnectionPrepare your 4-wire cable for direct connection Optional 3-Wire Connection Prepare your 3-wire cable for direct connectionVenting Requirements VentingOptional exhaust installations Recommended exhaust installationsAlternate installations for close clearances Plan Vent SystemInstall exhaust hood Install Vent SystemSpecial provisions for mobile home installations Connect vent to exhaust hoodRemove drain hose form floor drain installations only Attach drain hose to drain connectorConnect Drain Hose Attach clamp to drain hoseConnect Inlet Hoses Check for leaks Connect vent to exhaust outlet Connect Inlet Hoses Connect VentSecure drain hose Laundry Tub Standpipe WallLevel WASHER/DRYER Adjust leveling legsCheck levelness of washer/dryer Plug into a grounded 3- or 4-prong outletIf the dryer will not start, check the following Complete Installation ChecklistPage TM 2013 Whirlpool. All rights reserved