Frigidaire 137111500B installation instructions Table of Contents

Page 2

Table of Contents

Important Safety Instructions

................................................2

Installation Instructions

9-13

Pre-installation Requirements

................................................2

Reversing door

14-15

Installation Requirements

3-7

Accessories/Replacement parts

16

Installed Dimensions

8

Español

17

Important Safety Instructions

For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Recognize safety symbols, words and labels

Safety items throughout this manual are labeled with a WARNING or CAUTION based on the risk type as described:

This symbol alerts you to situations that may cause serious body harm, death or property damage.

This symbol alerts you to situations that may cause bodily injury or property damage.

- RISK OF FIRE - Read all of the following instructions before installing and using this appliance:

Destroy the carton and plastic bags after the dryer is unpacked. Children might use them for play. Cartons covered with rugs, bedspreads, or plastic sheets can become airtight chambers causing suffocation. Place all materials in a garbage container or make materials inaccessible to children.

Clothes dryer installation and service must be performed by a qualified installer, service agency or the gas supplier.

Install the clothes dryer according to the manufacturer’s instructions and local codes.

The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian electrical code C22.1 part 1.

The gas service to the dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas Code ANSI Z223.1, or in Canada, CAN/ACG B149.1-2000.

The dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 No. 112 (latest editions) for HOME USE only. This dryer is not recommended for commercial applications such as restaurants, beauty salons, etc.

Do not install a clothes dryer with flexible plastic venting material. Flexible venting materials are known to collapse, be eas- ily crushed and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.

The instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur. Good safe practice and caution MUST be applied when installing, operating and maintaining any appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Clear the room, building or area of all occupants.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Save these instructions for future reference.

Pre-Installation Requirements

Tools and materials needed for installation:

 

• Adjustable pliers

• Carpenter’s level

• Gas line shutoff valve (gas dryer)

• Phillips, straight, & square bit screw-

• External vent hood

• ½ NPT union flare adapters (x2) and

drivers

4-inch (10.2 cm), rigid metal or semi-

flexible gas supply line (gas dryer)

• Adjustable wrench

rigid metal exhaust duct work

• Metal foil tape (not duct tape)

• Pipe wrench for gas supply (gas dryer)

3-wire or 4-wire 240 volt cord kit

 

LP-resistant thread tape (for natural

(electric dryer)

 

gas or LP supply, gas dryer)

• 4 in. (10.2 cm) clamp

 

 

2

 

Image 2
Contents Installation Instructions Table of Contents Electrical requirements for electric dryer Electrical requirements for gas dryerGas supply requirements Exhaust system requirementsExhaust system requirements Manufactured or mobile home installation Exhaust directionDo not Install Your Dryer Clearance requirementsInstalled dryer dimensions Grounding requirements Electric dryer Canada Electrical installationGrounding requirements Electric dryer USA Grounding requirements Gas dryer USA and Canada Gas connectionElectrical connection non-Canada 3 wire cord Turn off power supply to outletElectrical connection non-Canada 4 wire cord General installation Window Door Reversal Instructions Page Accessories Replacement parts 1-800-944-9044 in CanadaÍndice Requisitos eléctricos de la secadora eléctrica Requisitos eléctricos de la secadora a gasRequerimientos del suministro de gas Requisitos del sistema de escapeRequisitos del sistema de escape continuación Longitud MáximaInstalación en una casa rodante Dirección del escapeRequisitos de despeje No Instale LA SecadoraDimensiones de la secadora instalada Instalación eléctrica Requisitos de conexión a tierra secadora eléctrica CanadáConexión de gas Flujo DE GASConexión eléctrica fuera de Canadá trifilar Tornillo VerdeConexión eléctrica fuera de Canadá tetrafilar Instalación general Conecte el tubo de escape al sistema de escape exteriorPage Page Accesorios Piezas de repuesto 1-800-944-9044 en Canada