Frigidaire 137111500B installation instructions Clearance requirements, Do not Install Your Dryer

Page 7

Clearance requirements

- EXPLOSION HAZARD - Do not install the dryer where gasoline or other flammables are kept or stored. If the dryer is installed in a garage, it must be a minimum of 18 inches (45.7 cm) above the floor. Failure to do so can result in death, explosion, fire or burns.

DO NOT INSTALL YOUR DRYER:

1.In an area exposed to dripping water or outside weather conditions.

2.In an area where it will come in contact with curtains, drapes, or anything that will obstruct the flow of com- bustion and ventilation air.

3.On carpet. Floor MUST be solid with a maximum slope of 1 inch (2.54 cm).

INSTALLATION IN A RECESS OR CLOSET

1.A dryer installed in a bedroom, bathroom, recess or closet, MUST be exhausted outdoors.

2.No other fuel burning appliance shall be installed in the same closet as the gas dryer.

3.Your dryer needs the space around it for proper ventilation.

DO NOT install your dryer in a closet with a solid door.

4.Closet door ventilation required: A minimum of 120 square inches (774.2 cm²) of opening, equally divided at the top and bottom of the door, is required. Openings should be located 3 inches (7.6 cm) from bottom and top of door. Openings are required to be unobstructed when a door is installed. A louvered door with equivalent air openings for the full length of the door is acceptable.

3” (7.6cm)

60 sq. in.

(387.1cm²)

60 sq. in.

(387.1cm²)

3” (7.6cm)

closet door

MINIMUM INSTALLATION CLEARANCES - Inches (cm)

 

SIDES

REAR

TOP

FRONT

 

 

 

 

 

Alcove

0” (0 cm)

0” (0 cm)*

0” (0 cm)

n/a

 

 

 

 

 

Under-

0” (0 cm)

0” (0 cm)*

0” (0 cm)

n/a

Counter

 

 

 

 

 

Closet

0” (0 cm)

0” (0 cm)*

0” (0 cm)

1” (2.54 cm)

 

 

 

 

 

*For other than straight back venting, a quick-turn 90° dryer vent elbow (vented right or down in free-standing dryer or right on pedestal-mounted dryer) must be installed to achieve 0” (0 cm) installation.

0” (0cm)

0” (0cm)

1”

0”

(2.54cm)

(0cm)

To achieve an installation with 0” (0 cm) clearance for the back of the dryer (for other than straight back vent- ing), a quick-turn 90° dryer vent elbow must be installed as described previously in this manual.

7

Image 7
Contents Installation Instructions Table of Contents Electrical requirements for gas dryer Electrical requirements for electric dryerExhaust system requirements Gas supply requirementsExhaust system requirements Exhaust direction Manufactured or mobile home installationClearance requirements Do not Install Your DryerInstalled dryer dimensions Grounding requirements Electric dryer USA Electrical installationGrounding requirements Electric dryer Canada Gas connection Grounding requirements Gas dryer USA and CanadaTurn off power supply to outlet Electrical connection non-Canada 3 wire cordElectrical connection non-Canada 4 wire cord General installation Window Door Reversal Instructions Page Replacement parts 1-800-944-9044 in Canada AccessoriesÍndice Requisitos eléctricos de la secadora a gas Requisitos eléctricos de la secadora eléctricaRequisitos del sistema de escape Requerimientos del suministro de gasLongitud Máxima Requisitos del sistema de escape continuaciónDirección del escape Instalación en una casa rodanteNo Instale LA Secadora Requisitos de despejeDimensiones de la secadora instalada Requisitos de conexión a tierra secadora eléctrica Canadá Instalación eléctricaFlujo DE GAS Conexión de gasTornillo Verde Conexión eléctrica fuera de Canadá trifilarConexión eléctrica fuera de Canadá tetrafilar Conecte el tubo de escape al sistema de escape exterior Instalación generalPage Page Piezas de repuesto 1-800-944-9044 en Canada Accesorios