Frigidaire 137111500B installation instructions Electrical requirements for electric dryer

Page 3

Electrical System Requirements

Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered gen- erators, solar powered generators, wind powered generators or any other generator other than the local utility company is not recommended.

Electrical requirements for electric dryer

CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.

POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.

This dryer is internally grounded to neutral unless it was manufactured for sale in Canada. Grounding through the neutral link is prohibited for: (1) new branch circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes do not permit grounding through the neutral.

OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord is accessible when the dryer is in the installed position.

GROUNDING CONNECTION - See “Grounding requirements” in Electrical Installation section.

3-WIRE POWER SUPPLY CORD KIT (not supplied)

4-WIRE POWER SUPPLY CORD KIT (not supplied)

3-wire receptacle

(NEMA type 10-30R)

The dryer MUST employ a 3-conductor power supply cord NEMA 10-30 type SRDT rated at 240 volt AC minimum, 30 amp, with 3 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. For 3-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.

4-wire receptacle

(NEMA type 14-30R)

The dryer MUST employ a 4-conductor power supply cord NEMA 14-30 type SRDT or ST (as required) rated at 240 volt AC minimum, 30 amp, with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers. For 4-wire cord connection instructions see ELECTRICAL CONNECTIONS FOR A 4-WIRE SYSTEM.

Dryers manufactured for sale in Canada have factory- installed, 4-wire power supply cord (NEMA 14-30R).

Electrical requirements for gas dryer

CIRCUIT - Individual, properly polarized and grounded 15 amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker.

POWER SUPPLY - 2-wire, with ground, 120 volt, single phase, 60 Hz, Alternating Current.

POWER SUPPLY CORD - The dryer is equipped with a 120 volt 3-wire power cord.

GROUNDING CONNECTION - See “Grounding requirements” in Electrical Installation section.

Grounding type wall receptacle

Do not, under

any circumstances, cut, remove,

or bypass the grounding prong.

Power cord with

3-prong grounded plug

3

Image 3
Contents Installation Instructions Table of Contents Electrical requirements for gas dryer Electrical requirements for electric dryerExhaust system requirements Gas supply requirementsExhaust system requirements Exhaust direction Manufactured or mobile home installationClearance requirements Do not Install Your DryerInstalled dryer dimensions Electrical installation Grounding requirements Electric dryer USAGrounding requirements Electric dryer Canada Gas connection Grounding requirements Gas dryer USA and CanadaTurn off power supply to outlet Electrical connection non-Canada 3 wire cordElectrical connection non-Canada 4 wire cord General installation Window Door Reversal Instructions Page Replacement parts 1-800-944-9044 in Canada AccessoriesÍndice Requisitos eléctricos de la secadora a gas Requisitos eléctricos de la secadora eléctricaRequisitos del sistema de escape Requerimientos del suministro de gasLongitud Máxima Requisitos del sistema de escape continuaciónDirección del escape Instalación en una casa rodanteNo Instale LA Secadora Requisitos de despejeDimensiones de la secadora instalada Requisitos de conexión a tierra secadora eléctrica Canadá Instalación eléctricaFlujo DE GAS Conexión de gasTornillo Verde Conexión eléctrica fuera de Canadá trifilarConexión eléctrica fuera de Canadá tetrafilar Conecte el tubo de escape al sistema de escape exterior Instalación generalPage Page Piezas de repuesto 1-800-944-9044 en Canada Accesorios