Frigidaire 137111500B installation instructions Exhaust system requirements

Page 5

Exhaust system requirements, continued

- FIRE HAZARD - A clothes dryer must be exhausted outdoors. Do not exhaust dryer into a chimney, a wall, a ceiling, an attic, a crawl space or any concealed space of a building. A clothes dryer produces combustible lint. If the dryer is not exhausted outdoors, some fine lint will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard.

The dryer must be connected to an exhaust outdoors. Regularly inspect the outdoor exhaust opening and remove any accumulation of lint around the outdoor exhaust opening and in the surrounding area.

- FIRE HAZARD -

Do not allow combustible materials (for example: clothing, draperies/curtains, paper) to come in contact with exhaust system. The dryer MUST NOT be exhausted into a chim- ney, a wall, a ceiling, or any concealed space of a building which can accumulate lint, resulting in a fire hazard.

Do not screen the exhaust ends of the vent system, or use any screws, rivets or other fasteners that extend into the duct to assemble the exhaust system. Lint can become caught in the screen, on the screws or rivets, clogging the duct work and creating a fire hazard as well as increasing drying times. Use an approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fittings MUST be installed downstream with the flow of air.

- FIRE HAZARD - Exceeding the length of duct pipe or number of elbows allowed in the “MAXIMUM LENGTH” charts can cause an accumulation of lint in the ex- haust system. Plugging the system could create a fire hazard, as well as increase drying times.

 

 

MAXIMUM LENGTH

 

Number

of 4” (10.2cm) Rigid Metal Duct

 

VENT HOOD TYPE

 

 

(Preferred)

 

of 90°

 

 

 

turns

 

 

 

4”

 

 

2.5”

(10.2cm)

louvered

(6.35cm)

0

64 ft. (19.5 m)

48 ft. (14.6 m)

1

52 ft. (15.9 m)

40 ft. (12.2 m)

2

44 ft. (13.5 m)

32 ft. (9.8 m)

3

32 ft. (9.8 m)

24 ft. (7.3 m)

4

28 ft. (9.5 m)

16 ft. (4.9 m)

- FIRE HAZARD -

Do not install flexible plastic or flexible foil venting mate- rial.

If installing semi-rigid venting, do not exceed 8 ft. (2.4 m) duct length.

Install male fittings in correct direction:

CORRECTINCORRECT

5

Image 5
Contents Installation Instructions Table of Contents Electrical requirements for gas dryer Electrical requirements for electric dryerExhaust system requirements Gas supply requirementsExhaust system requirements Exhaust direction Manufactured or mobile home installationClearance requirements Do not Install Your DryerInstalled dryer dimensions Grounding requirements Electric dryer Canada Electrical installationGrounding requirements Electric dryer USA Gas connection Grounding requirements Gas dryer USA and CanadaTurn off power supply to outlet Electrical connection non-Canada 3 wire cordElectrical connection non-Canada 4 wire cord General installation Window Door Reversal Instructions Page Replacement parts 1-800-944-9044 in Canada AccessoriesÍndice Requisitos eléctricos de la secadora a gas Requisitos eléctricos de la secadora eléctricaRequisitos del sistema de escape Requerimientos del suministro de gasLongitud Máxima Requisitos del sistema de escape continuaciónDirección del escape Instalación en una casa rodanteNo Instale LA Secadora Requisitos de despejeDimensiones de la secadora instalada Requisitos de conexión a tierra secadora eléctrica Canadá Instalación eléctricaFlujo DE GAS Conexión de gasTornillo Verde Conexión eléctrica fuera de Canadá trifilarConexión eléctrica fuera de Canadá tetrafilar Conecte el tubo de escape al sistema de escape exterior Instalación generalPage Page Piezas de repuesto 1-800-944-9044 en Canada Accesorios