ADC AD-170SE installation manual Preoperational Instructions, Compressed AIR Requirements

Page 40

K. PREOPERATIONAL INSTRUCTIONS

NON-COIN MODELS

1.To start the dryer:

a.Microprocessor Controller (Computer) Dryers...

1)The light emitting diode (L.E.D.) display will read “READY.”

2)Press the “E” on the keypad.

3)The dryer will start, and the L.E.D. display will show “MANUAL DRYING CYCLE E, DRYING TEMPERATURE 180º F, DRYING TIME 50 MINUTES.”

b.Dual Timer Dryers...

1)Turn drying timer knob for a time of 20 minutes.

2)Select “High Temp.”

3)Push “Push To Start” button.

4)To stop dryer, open the main door.

2.Spin and dwell (stop) times are adjustable at the reversing timer.

L.COMPRESSED AIR REQUIREMENTS

The dryer requires an external supply of compressed air (2.5 cfh [cubic feet per hour] @ 80 psi [0.07 cmh [cubic meters per hour] @ 5.51 bar] for gas models and 3.25 cfh @ 80 psi [0.09 cmh @ 5.51 bar] for steam models). For steam models, compressed air is necessary for the air operated steam damper. On both the steam models as well as the gas models, compressed air is necessary/required for blower air jet operation...to clean lint from the impellor/fan (squirrel cage).

1. Air Requirements

a. Microprocessor Controller (Computer) Dryers

Compressed Air Supply

Air Pressure

 

 

 

 

Normal

80 psi

5.51

bar

Minimum Supply

70 psi

4.82

bar

Maximum Supply

90 psi

6.21

bar

Shaded areas are stated in metric equivalents

36

Image 40
Contents AD-170SE Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Gas and Steam Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Page Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements General Exhaust Ductwork InformationAnywhere Downstream of the Dryer Page Page Page Page Electrical Information GAS and Steam Page Page GAS Information Type of GAS Page Page Operating Steam Pressure Steam InformationSteam Damper System Compressed Air Supply Air Pressure Page Preparation for OPERATION/START-UP Preoperational Test Basket Tumbler Coating Preoperational Instructions Compressed AIR RequirementsShutdown Instructions Service SERVICE/PARTS InformationParts Warranty Information Returning Warranty CardsWarranty Returning Warranty PartsPage Routine Maintenance CleaningSteam Dryers Adjustments LubricationPhase Manual Reset Burner HI-LIMIT InstructionsDual Timer Data Label Information Reversing Timer SPIN/DWELLADJUSTMENTS Timing LegendProcedure for Functional Check Replacement Components Page Installation Sensoractivated Fire Extinguishing S.A.F.E. SystemTypical water supply Optional Manual Bypass NON-COIN S.A.F.E. System Check Procedure System ResetF.E. System Theory of Operation Page ADC Part No 12 01/23/09