S.A.F.E. SYSTEM THEORY OF OPERATION
While the dryer is in an idle state or
While a drying cycle is in process and the heat has turned on at least once, the Phase 7 control monitors the exhaust temperature transducer. If the drying cycle temperature set point is set greater than 160° F (71° C) and the control detects an exhaust temperature rise 25° F greater than set point, this will be the trip point and the S.A.F.E. system routine will activate. If set point is below 160° F (71° C) the trip point will be 185° F (85° C).
Once the S.A.F.E. system routine is activated, water will be injected into the basket (tumbler) chamber. Anytime water is being injected into the basket (tumbler); the basket (tumbler) drive will turn the load for
SYSTEM RESET
After the microprocessor determines that the situation is under control and shuts the water being injected into the basket (tumbler) off, the microprocessor display will read “S.A.F.E. System activated,” and the horn/tone will sound until reset manually.
To reset the microprocessor once the control displays “S.A.F.E. System activated,” press the red “STOP” key on the keypad.
NON-COIN S.A.F.E. SYSTEM CHECK PROCEDURE
The operation of the water solenoid valve can be tested to ensure that the water supply system and valve are functional. Before attempting system check, be sure that ALL water supply shutoff valves to the dryer are in the OPEN position, and the dryer must be in the “READY” mode where no cycle is loaded or in progress.
The procedure is as follows:
1.Press and hold the red “STOP” key (while in “READY” mode and no cycle in progress).
2.Press and hold the “A” key.
3.Water valve will open and water will be dispensed into basket (tumbler) area as long as both keys are held.
IMPORTANT: This is a test function only and the keys should be held and system activated for only a second or so, otherwise water will accumulate in various places in the dryer.