A. SPECIFICATIONS

MAXIMUM CAPACITY (DRY WEIGHT)

 

170 lb

 

 

77.11 kg

TUMBLER DIAMETER

 

51-1/2”

 

130.81 cm

TUMBLER DEPTH

 

 

 

42-1/2”

 

107.95 cm

TUMBLER VOLUME

 

 

 

51.20 cu ft

 

1,449.82 L

TUMBLER/DRIVE MOTOR

 

1 hp

 

 

0.75 kW

BLOWER/FAN MOTOR

 

7-1/2 hp

 

 

5.59 kW

DOOR OPENING (DIAMETER)

 

31-3/8”

 

 

79.69 cm

DOOR SILL HEIGHT

 

 

 

33-3/8”

 

 

84.77 cm

WATER CONNECTION

 

3/4”-11.5 NH

(North America)

 

 

 

 

 

 

3/4” B.S.P.T. (Outside North America)

DRYERS PER 20’/40’ CONTAINER

 

 

3 / 7

 

DRYERS PER 48’/53’ TRUCK

 

 

8 / 9

 

 

VOLTAGE AVAILABLE

 

208-575V

3,4w

50/60 Hz

 

APPROXIMATE NET WEIGHT

 

2,103 lb

 

953.90 kg

 

APPROXIMATE SHIPPING WEIGHT

2,269 lb

 

1,029.20 kg

Gas

AIRFLOW

 

 

60 Hz

3,700 cfm

 

104.77 cmm

 

 

 

 

50 Hz

3,083 cfm

 

87.30 cmm

 

 

 

 

 

 

 

HEAT INPUT

 

 

 

550,000 Btu/hr

138,598 kcal/hr

 

EXHAUST CONNECTION (DIAMETER)

18”

 

 

45.72 cm

 

COMPRESSED AIR CONNECTION

1/4” Quick Connection

 

COMPRESSED AIR VOLUME

 

4.25 cfh

 

 

0.12 cmh

 

INLET PIPE CONNECTION

 

1-1/2” F.N.P.T.

 

 

 

 

 

 

1-1/2” B.S.P.T. (CE and Australia Only)

 

VOLTAGE AVAILABLE

 

416-460V

3,4w

50/60 Hz

Electric

APPROXIMATE NET WEIGHT

 

2,103 lb

 

953.90 kg

APPROXIMATE SHIPPING WEIGHT

2,269 lb

 

1,029.20 kg

AIRFLOW

 

 

60 Hz

3,700 cfm

 

104.77 cmm

 

 

 

 

 

 

 

 

 

50 Hz

3,083 cfm

 

87.30 cmm

 

EXHAUST CONNECTION (DIAMETER)

18”

 

 

45.72 cm

 

COMPRESSED AIR CONNECTION

1/4” Quick Connection

 

COMPRESSED AIR VOLUME

 

4.25 cfh

 

 

0.12 cmh

 

 

 

OVEN SIZE

 

 

 

 

 

 

kW

 

Btu/hr

 

kcal/hr

 

 

 

 

 

126

 

429,900

 

108,300

 

 

 

 

 

VOLTAGE AVAILABLE

 

208-575V

3,4w

50/60 Hz

 

APPROXIMATE NET WEIGHT

 

2,259 lb

 

1,024.67 kg

 

APPROXIMATE SHIPPING WEIGHT

2,425 lb

 

1,099.96 kg

Steam

AIRFLOW

 

 

60 Hz

4,400 cfm

 

124.59 cmm

 

 

 

 

50 Hz

3,666 cfm

 

103.80 cmm

 

 

 

 

 

 

 

STEAM CONSUMPTION

 

725 lb/hr

 

328.85 kg/hr

 

OPERATING STEAM PRESSURE

125 psi max

 

8.62 bar

 

EXHAUST CONNECTION (DIAMETER)

20”

 

 

50.80 cm

 

COMPRESSED AIR CONNECTION

1/4” Quick Connection

 

COMPRESSED AIR VOLUME

 

4.25 cfh

 

 

0.12 cmh

 

BOILER HORSEPOWER (NORMAL LOAD)

19 Bhp

 

 

 

 

SUPPLY CONNECTION

 

1-1/2” F.N.P.T.

 

 

 

RETURN CONNECTION

 

1-1/2” F.N.P.T.

 

 

Shaded areas are stated in metric equivalents

 

 

 

5/26/06

IMPORTANT: Gas dryers and steam dryers must be provided with a clean, dry, and regulated 80 psi

± 10 psi (5.51 bar ± 0.68 bar) air supply.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

6

Image 10
Contents AD-170SE Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Gas and Steam Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Page Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements General Exhaust Ductwork InformationAnywhere Downstream of the Dryer Page Page Page Page Electrical Information GAS and Steam Page Page GAS Information Type of GAS Page Page Operating Steam Pressure Steam InformationSteam Damper System Compressed Air Supply Air Pressure Page Preparation for OPERATION/START-UP Preoperational Test Basket Tumbler Coating Preoperational Instructions Compressed AIR RequirementsShutdown Instructions Service SERVICE/PARTS InformationParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningSteam Dryers Adjustments LubricationPhase Manual Reset Burner HI-LIMIT InstructionsDual Timer Data Label Information Reversing Timer SPIN/DWELLADJUSTMENTS Timing LegendProcedure for Functional Check Replacement Components Page Installation Sensoractivated Fire Extinguishing S.A.F.E. SystemTypical water supply Optional Manual Bypass NON-COIN S.A.F.E. System Check Procedure System ResetF.E. System Theory of Operation Page ADC Part No 12 01/23/09