ADC AD-170SE installation manual Type of GAS

Page 30

2.Technical Data

a. Gas Specifications

 

TYPE OF GAS

 

 

 

 

 

 

 

NATURAL

LIQUID PROPANE

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

 

 

 

 

 

Shaded areas are stated in metric equivalents

*Measured at the gas valve pressure tap when the gas valve is on.

b.Gas Connections:

Inlet connection --- 1-1/2” F.P.T.

Inlet supply size --- 1-1/2” N.P.T. (minimum) Btu/hr input -------- 550,000 (138,600 kcal/hr)

1)Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

 

 

 

TYPE OF GAS

 

Liquid

 

 

 

 

 

 

 

 

 

Propane

 

 

 

Natural

 

 

Liquid Propane

Btu/hour

kcal/hr

 

 

 

Conversion Kit

 

 

 

 

 

 

 

Rating

Rating

Qty.

D.M.S.*

 

Part No.

Qty.

D.M.S.*

Part No.

Part Number

 

 

 

 

 

 

 

 

 

 

550,000

138,600

4

#2

 

140839

4

#29

140820

880978

 

 

 

 

 

 

 

 

 

 

Shaded area is stated in metric equivalent

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas

#2 = 0.2210”

(5.6134 mm).

Liquid Propane Gas

#29 = 0.1360”

(3.4544 mm).

26

Image 30
Contents AD-170SE Installation Manual Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Gas and Steam Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Page Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements General Exhaust Ductwork InformationAnywhere Downstream of the Dryer Page Page Page Page Electrical Information GAS and Steam Page Page GAS Information Type of GAS Page Page Operating Steam Pressure Steam InformationSteam Damper System Compressed Air Supply Air Pressure Page Preparation for OPERATION/START-UP Preoperational Test Basket Tumbler Coating Preoperational Instructions Compressed AIR RequirementsShutdown Instructions SERVICE/PARTS Information ServiceParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningSteam Dryers Adjustments LubricationManual Reset Burner HI-LIMIT Instructions PhaseDual Timer Data Label Information Reversing Timer SPIN/DWELLADJUSTMENTS Timing LegendProcedure for Functional Check Replacement Components Page Installation Sensoractivated Fire Extinguishing S.A.F.E. SystemTypical water supply Optional Manual Bypass System Reset NON-COIN S.A.F.E. System Check ProcedureF.E. System Theory of Operation Page ADC Part No 12 01/23/09