2.Electrical Service Specifications
IDG-170 (Gas)
IDS-170 (Steam)
ELECTRIC SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. | When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. | ||||||||
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes | |||||||||
| to lised appliance amp draw data. |
|
|
|
|
| |||
B. Circuit breakers are thermal magnetic (industrial) motor curve type ONLY. For others, calculate/verify | |||||||||
correct breaker size according to appliance amp draw rating and type of breaker used. |
| ||||||||
C . Circuit breakers for |
|
| |||||||
SERVICE |
|
| WIRE |
| APPROX. | MINIMUM | FUSING | CIRCUIT | |
| PHASE |
| AMP DRAW |
| |||||
| Dual Element | ||||||||
VOLTAGE | SERVICE |
| WIRE SIZE | BREAKER | |||||
|
| 60 Hz | 50 Hz | Time Delay | |||||
208 |
| 3ø | 3 |
| 30 | 30 | * | 50 | 60 |
|
|
|
|
|
|
|
|
|
|
230/240 |
| 3ø | 3 |
| 29 | * | 40 | 60 | |
|
|
|
|
|
|
|
|
|
|
380 |
| 3ø | 3/4 |
| 16 | * | 25 | 30 | |
|
|
|
|
|
|
|
|
|
|
416 |
| 3ø | 3/4 |
| 16 | * | 25 | 30 | |
|
|
|
|
|
|
|
|
|
|
440 |
| 3ø | 3/4 |
| 15 | * | 25 | 30 | |
|
|
|
|
|
|
|
|
|
|
480 |
| 3ø | 3/4 |
| 15 | * | 25 | 30 | |
|
|
|
|
|
|
|
|
|
|
*AWG Stranded Type Wire...size wire as per National Electrical Code or local codes.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel area behind the top control (access) door. In the case of 208 VAC or 230/240 VAC, the supply voltage must match the electric service specifications of the data label exactly.
WARNING: 208 VAC AND 230/240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.
23