American Dryer Corp ID-170 Compressed AIR Requirements, Compressed AIR Pressure AIR Supply

Page 42

K. COMPRESSED AIR REQUIREMENTS

The model ID-170 dryer requires an external supply of compressed air (2.5 cfh @ 80 PSI [0.07 cmh @ 5.51 bars] for gas models and 3.25 cfh @ 80 PSI [0.09 cmh @ 5.51 bars] for steam models). For steam models, compressed air is necessary for the air operated steam damper. On both the steam model as well as the gas models, compressed air is necessary/required for blower air jet operation...to clean lint from the impellor/fan (squirrel cage).

1.Air Requirements

a. Microprocessor controller (computer) dryers...

COMPRESSED

AIR PRESSURE

AIR SUPPLY

 

 

 

 

 

Normal

80 PSI

5.51 bars

 

 

 

Minimum Supply

70 PSI

4.82 bars

 

 

 

Maximum Supply

90 PSI

6.21 bars

 

 

 

Shaded areas are stated in metric equivalents

2.Air Regulation

a.No air regulation or air filtration is provided with the dryer. External regulation/filtration of 80 PSI (5.51 bars) must be provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved.

3.Air Connection

a.Air connection to this system is a 1/8” F.P.T. as per the illustration below.

38

Image 42
Contents ID-170 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Routine Maintenance Important Information Receiving and HandlingSafety Precautions What to do if YOU Smell GASStandards SPECIFICATIONS/COMPONENT Identification SpecificationsSpecifications Component Identification Page Installation Procedures Location RequirementsUNPACKING/SETTING UP Page Page Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Page Page Page Page Page Electrical Information Electrical RequirementsIDG-170 Gas IDS-170 Steam Page Page GAS Information Type of GAS Page Page Steam Information Operating Steam PressureSteam Damper System Compressed AIR Pressure Page Electric Service Exactly Preparation for OPERATION/START-UPPreoperational Tests Basket Coating Page Compressed AIR Requirements Compressed AIR Pressure AIR SupplyShut Down Instructions SERVICE/PARTS Information ServiceParts Warranty Warranty InformationReturning Warranty Cards Returning Warranty PartsPage Routine Maintenance CleaningSteam Dryers Adjustments LubricationReversing Timer SPIN/DWELL Adjustments Timing LegendData Label Information Data LabelSerial Number Procedure for Functional Check Replacement Components P O RTA N T ADC 113331 1 08/27/01-25