K. COMPRESSED AIR REQUIREMENTS
The model
1.Air Requirements
a. Microprocessor controller (computer) dryers...
COMPRESSED | AIR PRESSURE | ||
AIR SUPPLY | |||
|
| ||
|
|
| |
Normal | 80 PSI | 5.51 bars | |
|
|
| |
Minimum Supply | 70 PSI | 4.82 bars | |
|
|
| |
Maximum Supply | 90 PSI | 6.21 bars | |
|
|
|
Shaded areas are stated in metric equivalents
2.Air Regulation
a.No air regulation or air filtration is provided with the dryer. External regulation/filtration of 80 PSI (5.51 bars) must be provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved.
3.Air Connection
a.Air connection to this system is a 1/8” F.P.T. as per the illustration below.
38