American Dryer Corp ML-82 III installation manual Gas and Steam

Page 21

2.Electrical Service Specifications

Gas and Steam

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)

IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.

B.Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

CIRCUIT

AMP DRAW

VOLTAGE

SERVICE

BREAKER

 

60 Hz

50 Hz

 

 

 

 

 

 

 

 

 

 

208

3

14.4

20

240

3

14.0

15.9

20

380-400

4*

8.4

15

416

4*

8.7

15

440

4*

8.6

15

460/480

3

7.5

15

* Contact factory for 3-wire system.

 

 

 

8/4/08

IMPORTANT: The dryer must be connected to the electric supply shown on the data label. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME. Any damage done to dryer components due to improper voltage connections will automatically VOID THE WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

3.Electrical Connections

NOTE: A wire diagram is located in the front electrical control box for connection data.

NOTE: A CIRCUIT SERVICING EACH DRYER MUST BE PROVIDED.

113344 - 9

www.amdry.com

17

Image 21
Contents ML-82 III Installation Manual ML-82 For Your Safety Page Table of Contents Section Safety PrecautionsStandards Specifications SPECIFICATIONS/COMPONENT IdentificationSpecifications Component Identification 113344 Location Requirements Installation ProceduresThis Exhaust Duct Transition Piece Must be Installed First UNPACKING/SETTING UPDryer Enclosure Requirements Fresh AIR Supply Requirements General Exhaust Ductwork Information Exhaust Requirements113344 American Dryer Corp 113344 113344 Electrical Requirements Electrical InformationGas and Steam GAS Information Type of GAS Type of GAS 113344 Steam Information Operating Steam Pressure113344 Compressed Air Pressure Air Supply Before YOU Start Check Local Codes and Permits Fire Suppression SystemAmerican Dryer Corp 113344 Typical water supply Preparation for OPERATION/START-UP Preoperational Test Basket Tumbler Coating Shutdown Instructions Preoperational InstructionsSERVICE/PARTS Information ServiceParts Returning Warranty Cards Warranty InformationWarranty Returning Warranty PartsAmerican Dryer Corp 113344 Routine Maintenance CleaningSuggested Cleaning Schedule Lubrication AdjustmentsLint Drawer Removal Procedure for Functional Check Replacement Components 113344 Data Label Information SectionviiiManual Reset Burner HI-LIMIT Instructions PhaseDual Timer ADC Part No 09/04/08