F. ELECTRICAL INFORMATION

1.ELECTRICAL REQUIREMENTS

It is your responsibility to have ALL electrical connections made by a properly licensed and component electrician to assure that the electrical installation is adequate and conforms with local and state regulations or codes. In the absence of such codes, ALL electrical connections, material, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in CANADA, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.

IMPORTANT: Failure to comply with these codes or ordinances or requirements stipulated in this manual can result in personal injury or component failure.

NOTE: Component failure due to improper installation will VOID THE WARRANTY.

Each dryer should be connected to an independtly protected branch circuit. The dryer must be connected with copper wire only. DO NOT use aluminum wire which could cause a fire hazard. The copper conductor wire/ cable must be of proper ampacity and insulation in accordance with electric codes for making ALL service connections.

NOTE: The use of aluminum wire will VOID THE WARRANTY.

NOTE: Wiring diagrams are afficed to the inside at the top front control door and to the rear upper back guard/panel.

18

Image 22
Contents What do YOU do if YOU Smell GAS QUE Faire SI Vous Sentez UNE Odeur DE GAZFor Your Safety Pour Votre Sécurité Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Routine Maintenance Section Important InformationSafety Precautions What to do if YOU Smell GASPage Section Specifications ML-79 WET Wash Component Identification Illus. No DescriptionInstallation Procedures Location RequirementsUnpacking and Setting UP Leveling DryerDryer Enclosure Requirements Make UP AIR Requirements Page Exhaust Requirements Page Page Be centered within this opening Electrical Information Electrical RequirementsElectrical Service Specifications GroundingElectrical Connections GAS Information Technical GAS DataS. Drill Material Size equivalent are as follows Page Page AIR Information Preparation for Operation and START-UP Preoperational Tests Gas DryersPreoperational Instructions Shut Down InstructionsService Service and Parts InformationParts Warranty Information Returning Warranty CardsPage Routine Maintenance CleaningDays Section Microprocessor Computer Models GAS Models Electric Models Low or inconsistent gas pressure Electric DryersPage Page Technical Information Data LabelProcedure for Functional Check Replacement Components Page Aquatex Humidity Sensor Instructions Figure #1ADC 07/29/99-25 12/08/00-10