American Dryer Corp ML-79 manual

Page 47

e.Open main door. The dryer must stop and ALL indicator lights on the back side of the microprocessor (computer) board must go out. (Refer to illustration on previous page [page 40]).

f.Try to restart the dryer with the main door open.

g.The microprocessor (computer) board’s L.E.D. must read “DOOR.”

h.Close the main door and restart the dryer.

i.Functional check of microprocessor (computer) board is complete.

2. Direct Spark Ignition (DSI) System

a. Upon completing installation of the replacement Direct Spark Ignition (DSI) module, reestablish power to the dryer.

b. Start the drying cycle.

c. The ignition (DSI) module’s L.E.D. indicator will light “red” for up to approximately 1.5 sec- onds (pre-purge time).

d. The module’s indicator light will then turn “green.” The gas valve will be energized and the ignitor probe will spark for approximately 8 seconds. The burner flame should now be estab- lished.

e. With the burner flame on, remove the flame sen- sor wire from the FS terminal of the DSI mod- ule.

f. The burner flame must shut off and the igni- tion module must lock out with the DSI module’s indicator light “red.”

g.Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

h.The ignition module must proceed through the pre-purge, with the indicator light “red,” the ignition trial time of approximately 8 seconds, with the indicator light “green,” and then proceed to lock out with the indicator light “red.”

i.Functional check of the Direct Spark Ignition (DSI) Module is complete.

1. Replace the flame sensor wire from the FS terminal to the DSI module.

43

Image 47
Contents QUE Faire SI Vous Sentez UNE Odeur DE GAZ What do YOU do if YOU Smell GASRetain This Manual In a Safe Place For Future Reference For Your Safety Pour Votre SécuritéFor Your Safety Page Table of Contents Section Routine Maintenance Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsPage Section Specifications ML-79 WET Wash Illus. No Description Component IdentificationLocation Requirements Installation ProceduresLeveling Dryer Unpacking and Setting UPDryer Enclosure Requirements Make UP AIR Requirements Page Exhaust Requirements Page Page Be centered within this opening Electrical Requirements Electrical InformationGrounding Electrical Service SpecificationsElectrical Connections Technical GAS Data GAS InformationS. Drill Material Size equivalent are as follows Page Page AIR Information Preparation for Operation and START-UP Gas Dryers Preoperational TestsShut Down Instructions Preoperational InstructionsParts Service and Parts InformationService Returning Warranty Cards Warranty InformationPage Cleaning Routine MaintenanceDays Section Microprocessor Computer Models GAS Models Electric Models Electric Dryers Low or inconsistent gas pressurePage Page Data Label Technical InformationProcedure for Functional Check Replacement Components Page Figure #1 Aquatex Humidity Sensor InstructionsADC 07/29/99-25 12/08/00-10