American Dryer Corp ML-79 manual Aquatex Humidity Sensor Instructions, Figure #1

Page 48

AQUATEX HUMIDITY SENSOR INSTRUCTIONS

1.Before operating machine, the humidity behind control door must be placed on the outer top of dryer.

2.Install sensor by running the sensor through the hole in the outer top of dryer. See figure #1.

3.Insert rubber grommet that is on humidity sensor wire, in hole on outer top.

figure #1

4.Place humidity sensor in grommet as in figure #2. The humidity sensor must be free from all obstruc- tions in order for proper operation. See figure #2.

figure #2

44

Image 48
Contents What do YOU do if YOU Smell GAS QUE Faire SI Vous Sentez UNE Odeur DE GAZFor Your Safety Pour Votre Sécurité Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Routine Maintenance Section Important InformationSafety Precautions What to do if YOU Smell GASPage Section Specifications ML-79 WET Wash Component Identification Illus. No DescriptionInstallation Procedures Location RequirementsUnpacking and Setting UP Leveling DryerDryer Enclosure Requirements Make UP AIR Requirements Page Exhaust Requirements Page Page Be centered within this opening Electrical Information Electrical RequirementsElectrical Service Specifications GroundingElectrical Connections GAS Information Technical GAS DataS. Drill Material Size equivalent are as follows Page Page AIR Information Preparation for Operation and START-UP Preoperational Tests Gas DryersPreoperational Instructions Shut Down InstructionsService and Parts Information ServiceParts Warranty Information Returning Warranty CardsPage Routine Maintenance CleaningDays Section Microprocessor Computer Models GAS Models Electric Models Low or inconsistent gas pressure Electric DryersPage Page Technical Information Data LabelProcedure for Functional Check Replacement Components Page Aquatex Humidity Sensor Instructions Figure #1ADC 07/29/99-25 12/08/00-10