American Dryer Corp ML-79 manual Low or inconsistent gas pressure, Electric Dryers

Page 42

ELECTRIC MODELS

1.Failed oven contactor or coil.

2.Failed electric heating elements. P. Dryer is taking too long to dry.

1.Exhaust duct work too long or is undersized, back pressure cannot exceed .3 inches water column.

2.Restriction in exhaust.

a.Dryer back draft damper is sticking partially closed.

b.Restriction or obstruction in duct work.

1.) Check duct work all the way to the outdoors.

3.Insufficient make up air.

4.Impellor and fan is rotating in the wrong direction only (3 phase models only).

5.Lint screen is dirty or is not being cleaned often enough.

6.Inadequate air flow.

a.Impellor and fan failure.

7.GAS MODELS

a.Low or inconsistent gas pressure.

Natural gas pressure must be between 3.5 and 4 inches of water column. L.P. gas pressure must be between 10.5 and 11 inches of water column.

b.Poor air and gas mixture (too much gas or not enough air) at burner, yellow or poor flame pattern. 1.) Not enough make-up air.

2.) Restriction in exhaust.

3.) Gas pressure too high.

4.) Impellor and fan rotating in the wrong direction (3 phase models).

5.) Burner orifice size (D.M.S.) too large for application (i.e. high elevation).

c.Sail switch is fluttering.

1.) Restriction in exhaust.

a.)) Lint screen is dirty or is not being cleaned often enough. d. Failed burner hi-limit switch, opens at incorrect temperature.

e. Gas supply may have low heating value.

8.ELECTRIC DRYERS

a.Not enough make up air.

b.Restriction in exhaust.

c.Lint screen is dirty or is not being cleaned often enough.

d.Blower and fan is rotating in the wrong direction (3 phase models only).

38

Image 42
Contents What do YOU do if YOU Smell GAS QUE Faire SI Vous Sentez UNE Odeur DE GAZFor Your Safety Pour Votre Sécurité Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Routine Maintenance Section Important InformationSafety Precautions What to do if YOU Smell GASPage Section Specifications ML-79 WET Wash Component Identification Illus. No DescriptionInstallation Procedures Location RequirementsUnpacking and Setting UP Leveling DryerDryer Enclosure Requirements Make UP AIR Requirements Page Exhaust Requirements Page Page Be centered within this opening Electrical Information Electrical RequirementsElectrical Service Specifications GroundingElectrical Connections GAS Information Technical GAS DataS. Drill Material Size equivalent are as follows Page Page AIR Information Preparation for Operation and START-UP Preoperational Tests Gas DryersPreoperational Instructions Shut Down InstructionsService and Parts Information ServiceParts Warranty Information Returning Warranty CardsPage Routine Maintenance CleaningDays Section Microprocessor Computer Models GAS Models Electric Models Low or inconsistent gas pressure Electric DryersPage Page Technical Information Data LabelProcedure for Functional Check Replacement Components Page Aquatex Humidity Sensor Instructions Figure #1ADC 07/29/99-25 12/08/00-10