American Dryer Corp ML-79 manual Preoperational Tests, Gas Dryers

Page 31

J. PREOPERATIONAL TESTS

ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.

1.Turn on electric power to the dryer.

a.Open ALL shut-off valves (gas models only).

2.Refer to the operating instructions for starting your particular model dryer.

3.Gas Dryers

a.When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air to be purged from the lines.

NOTE: Purging period, check to be sure that ALL gas shut-off valves are open.

NOTE: Gas dryers are equipped with a direct spark ignition (DSI) system which has internal diagnostics. If ignition is not established the heat circuit in the DSI module will lock out until it is manually reset. To reset the DSI system, open and close the main door and restart the dryer.

b.A gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column pressure is correct and consistent.

NOTE: Water column pressure requirements, measured at the pressure tap of the gas valve body: Natural Gas 3.5 inch water column

L.P. Gas 10.5 inch water column

IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank), or an external regulator must be added to each dryer.

Electrically Heated Dryers

a.Check to ensure electric oven and contactor assembly is activating.

4.Make a complete operational check of ALL safety related circuits:

a.Door Switches

b.Hi-Limit thermostats

c.Sail Switch (for gas and electric models only)

27

Image 31
Contents QUE Faire SI Vous Sentez UNE Odeur DE GAZ What do YOU do if YOU Smell GASRetain This Manual In a Safe Place For Future Reference For Your Safety Pour Votre SécuritéFor Your Safety Page Table of Contents Section Routine Maintenance Important Information SectionWhat to do if YOU Smell GAS Safety PrecautionsPage Section Specifications ML-79 WET Wash Illus. No Description Component IdentificationLocation Requirements Installation ProceduresLeveling Dryer Unpacking and Setting UPDryer Enclosure Requirements Make UP AIR Requirements Page Exhaust Requirements Page Page Be centered within this opening Electrical Requirements Electrical InformationGrounding Electrical Service SpecificationsElectrical Connections Technical GAS Data GAS InformationS. Drill Material Size equivalent are as follows Page Page AIR Information Preparation for Operation and START-UP Gas Dryers Preoperational TestsShut Down Instructions Preoperational InstructionsService Service and Parts InformationParts Returning Warranty Cards Warranty InformationPage Cleaning Routine MaintenanceDays Section Microprocessor Computer Models GAS Models Electric Models Electric Dryers Low or inconsistent gas pressurePage Page Data Label Technical InformationProcedure for Functional Check Replacement Components Page Figure #1 Aquatex Humidity Sensor InstructionsADC 07/29/99-25 12/08/00-10