American Dryer Corp ML-130DR, ML-130 III Procedure for Functional Check Replacement Components

Page 25

Procedure for Functional Check

of Replacement Components ________

Microprocessor Controller (Computer) Board

Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer.

Start the drying cycle by pressing any of the preset cycles in letters A-F.

Verify that the applicable indicator lights on the microprocessor controller (computer) board are lit. (Refer to the illustration below.)

For Models with DSI Module (Type I)

Theory of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (6-seconds), the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open as long as there is a call for heat. The DSI module will “LOCKOUT” if the gas burner flame is not sensed at the end of the trial for ignition period. The trial for ignition period will be repeated for a total of 3 retries/trials (the initial try and 2 more retries/ trials). If the flame is not sensed at the end of the third retry/ trial (inter-purge period of 30-seconds) the DSI module will “LOCKOUT” (L.E.D. diagnostic indicator flashes).

A steady L.E.D. indicator indicates normal operation.

No L.E.D. indicator indicates a power or an internal failure has occurred.

For Models with DSI Module (Type II)

Theory of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (8-seconds), the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open as long as there is a call for heat. The DSI module will “LOCKOUT” if the gas burner flame is not sensed at the end of the trial for ignition period. The trial for ignition period will be repeated for a total of 3 retries/trials (the initial try and 2 more retries/ trials). If the flame is not sensed at the end of the third retry/ trial (inter-purge period of 30-seconds), the DSI module will “LOCKOUT” (a red L.E.D. diagnostic indicator will flash).

An unlit red L.E.D. diagnostic indicator indicates normal operation.

A lit green L.E.D. diagnostic indicator indicates dryer controller is calling for heat and that all interlocks have been satisfied.

113335 - 12

www.amdry.com

25

Image 25
Contents American Dryer Corporation ML-130 III / ML-130DR Installation ManualDate of Purchase Model no RESELLER’S Name Serial Numbers Retain This Manual in a Safe Place for Future ReferenceTable of Contents What To Do If You Smell Gas Safety PrecautionsPersonal injury or fire could result 113335 Electric ML-130 SpecificationsML-130 Specifications ML-130DR Specifications ML-130DR Specifications Unpacking/Setting Up Installation ProceduresLocation Requirements Leveling DryerTo Remove Top Console Module Dryer Enclosure RequirementsExhaust Transition Piece Gas and Electric Only Exhaust Requirements Fresh Air Supply RequirementsGeneral Exhaust Ductwork Information Single Dryer Venting Outside Ductwork ProtectionML-130 Multiple Dryer Common VentingElectrical Information Electrical Service SpecificationsML-130DR Multiple Dryer Venting Electrical RequirementsGas Model and Steam Model Dryers Electrical ConnectionsElectric Model Dryers Grounding Gas InformationGas Supply Fire or explosion could resultML-130DR ML-130Steam Information Installation InstructionsSteam Coil pH Level Steam Requirements, High PressureAir Requirements Compressed Air Supply Air Pressure Steam Damper Air System ConnectionsAir Connection Steam Damper System OperationPreoperational Test Preparation for OperationHeat Circuit Operational Test Gas Models Electric ModelsOperating Instructions Shutdown InstructionsWarranty Information Service/Parts InformationRoutine Maintenance Data Label Information Reversing Timer Spin/Dwell AdjustmentsLubrication Microprocessor Controller Computer Board Procedure for Functional Check Replacement ComponentsFor Models with DSI Module Type Fire Suppression System Manual Reset Burner Hi-Limit InstructionsTypical water supply Optional Manual Bypass ADC Part No 12 07/31/08