American Dryer Corp ML-130 III, ML-130DR installation manual ML-130 Specifications, Electric

Page 6

ML-130 Specifications _____________________________________________________________

MAXIMUM CAPACITY (DRY WEIGHT)

120 lb

 

 

 

54.43 kg

TUMBLER DIAMETER

 

44.63”

 

 

113.35 cm

TUMBLER DEPTH

 

 

 

42-1/8”

 

 

 

107 cm

TUMBLER VOLUME

 

38.10 cu ft

 

 

1078.872 L

TUMBLER/DRIVE MOTOR

 

3/4 hp

 

 

 

0.56 kW

BLOWER/FAN MOTOR

 

3 hp

 

 

 

2.24 kW

DOOR OPENING (DIAMETER)

 

31-3/8”

 

 

 

79.69 cm

DOOR SILL HEIGHT

 

25-7/8”

 

 

 

65.72 cm

WATER CONNECTION

 

3/4”-11.5 NH

DRYERS PER 20’/40’ CONTAINER

 

 

 

3 / 7

 

DRYERS PER 48’/53’ TRUCK

 

 

9 / 10

 

 

VOLTAGE AVAILABLE

 

208-575v

 

3,4w

50/60 Hz

 

APPROX. NET WEIGHT

 

1,260 lb

 

 

 

571.53 kg

 

APPROX. SHIPPING WEIGHT

1,400 lb

 

 

 

635.03 kg

Gas

AIRFLOW

 

 

60 Hz

2,150 cfm

 

 

60.88 cmm

 

 

 

 

50 Hz

1,792 cfm

 

 

50.73 cmm

 

 

 

 

 

 

 

 

HEAT INPUT

 

375,000 Btu/hr

 

94,498 kcal/hr

 

EXHAUST CONNECTION (DIAMETER)

14”

 

 

 

35.56 cm

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

COMPRESSED AIR VOLUME

 

N / A

 

 

INLET PIPE CONNECTION

 

 

1” F.N.P.T.

 

 

VOLTAGE AVAILABLE

 

208-600v

 

3,4w

50/60 Hz

 

APPROX. NET WEIGHT

 

1,260 lb

 

 

 

571.53 kg

Electric

APPROX. SHIPPING WEIGHT

1,400 lb

 

 

 

635.03 kg

AIRFLOW

 

 

60 Hz

2,150 cfm

 

 

60.88 cmm

 

 

 

 

50 Hz

1,792 cfm

 

 

50.73 cmm

 

 

 

 

 

 

 

 

EXHAUST CONNECTION (DIAMETER)

14”

 

 

 

35.56 cm

 

COMPRESSED AIR CONNECTION

 

N / A

 

 

COMPRESSED AIR VOLUME

 

N / A

 

 

 

 

OVEN SIZE

 

 

 

 

 

 

 

kW

 

Btu/hr

 

kcal/hr

 

 

 

 

 

 

72

 

245,729

 

61,923

 

 

 

 

 

 

75.6

 

258,023

 

65,021

 

 

 

 

 

 

VOLTAGE AVAILABLE

 

208-575v

 

3,4w

50/60 Hz

 

APPROX. NET WEIGHT

 

1,421 lb

 

 

 

644.55 kg

 

APPROX. SHIPPING WEIGHT

1,561 lb

 

 

 

708.06 kg

Steam

AIRFLOW

 

 

60 Hz

2,150 cfm

 

 

60.88 cmm

 

 

 

 

50 Hz

1,792 cfm

 

 

50.73 cmm

STEAM CONSUMPTION

 

450 lb/hr

 

 

204.12 kg/hr

 

 

 

 

 

OPERATING STEAM PRESSURE

125 psi max

 

 

8.62 bar

 

EXHAUST CONNECTION (DIAMETER)

14”

 

 

 

35.56 cm

 

COMPRESSED AIR CONNECTION

1/4” Quick Connection

 

COMPRESSED AIR VOLUME

4.25 cfh

 

 

 

0.12 cmh

 

BOILER HP (NORMAL LOAD)

 

13 Bhp

 

 

SUPPLY CONNECTION

 

1-1/4” F.N.P.T.

 

RETURN CONNECTION

 

1-1/4” F.N.P.T.

Shaded areas are stated in metric equivalents

 

 

 

 

 

9/27/04

IMPORTANT: Steam dryers must be provided with a clean, dry, and regulated 80 psi +/- 10 psi (5.51 bar +/- 0.68 bar) air supply.

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

6

American Dryer Corp.

113335 - 12

Image 6
Contents ML-130 III / ML-130DR Installation Manual American Dryer CorporationRetain This Manual in a Safe Place for Future Reference Date of Purchase Model no RESELLER’S Name Serial NumbersTable of Contents Safety Precautions What To Do If You Smell GasPersonal injury or fire could result 113335 ML-130 Specifications ElectricML-130 Specifications ML-130DR Specifications ML-130DR Specifications Location Requirements Installation ProceduresUnpacking/Setting Up Leveling DryerDryer Enclosure Requirements To Remove Top Console ModuleExhaust Transition Piece Gas and Electric Only Fresh Air Supply Requirements Exhaust RequirementsGeneral Exhaust Ductwork Information ML-130 Outside Ductwork ProtectionSingle Dryer Venting Multiple Dryer Common VentingML-130DR Multiple Dryer Venting Electrical Service SpecificationsElectrical Information Electrical RequirementsElectrical Connections Gas Model and Steam Model DryersElectric Model Dryers Gas Supply Gas InformationGrounding Fire or explosion could resultML-130 ML-130DRSteam Coil pH Level Installation InstructionsSteam Information Steam Requirements, High PressureAir Connection Steam Damper Air System ConnectionsAir Requirements Compressed Air Supply Air Pressure Steam Damper System OperationHeat Circuit Operational Test Gas Models Preparation for OperationPreoperational Test Electric ModelsShutdown Instructions Operating InstructionsService/Parts Information Warranty InformationRoutine Maintenance Reversing Timer Spin/Dwell Adjustments Data Label InformationLubrication Procedure for Functional Check Replacement Components Microprocessor Controller Computer BoardFor Models with DSI Module Type Manual Reset Burner Hi-Limit Instructions Fire Suppression SystemTypical water supply Optional Manual Bypass ADC Part No 12 07/31/08