American Dryer Corp AD-24 Phase 7 installation manual Do not Reduce this Pipe Size Requirement

Page 27

3.Piping Connections

ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance Btu being supplied.

The dryer is provided with a 1/2” N.P.T. inlet pipe connection located at the right side of the base of the dryer. The minimum pipe size (supply line) to the dryer is 1/2” pipe. For ease in servicing, the gas supply line of each dryer must have its own shutoff valve.

IMPORTANT: The gas supply line to each dryer must be a minimum of 1/2-inch (12.7 mm).

DO NOT REDUCE THIS PIPE SIZE REQUIREMENT.

The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same line, etc. Specific information regarding supply line size should be determined by the gas supplier.

NOTE: Undersized gas supply piping can create a low or inconsistent pressure, which will result in erratic operation of the burner ignition system.

113222 - 5

www.amdry.com

23

Image 27
Contents AD-24 Installation Manual Retain This Manual in a Safe Place for Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check Section Safety PrecautionsAmerican Dryer Corp 113222 71.91 cm SpecificationsSpecifications Installation Procedures UNPACKING/SETTING UPLocation of the Dryer Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Single Dryer Venting 113222 American Dryer Corp 113222 Important Venting Reminders Electrical Requirements Electrical InformationGas American Dryer Corp 113222 Single-Phase Electrical Lead Connections American Dryer Corp 113222 GAS Information Type of GAS Do not Reduce this Pipe Size Requirement Preoperational Tests Preparation for OPERATION/START-UPBasket Tumbler Coating Preoperational Instructions Coin Models NON-COIN Models Dual Timer DryersShutdown Instructions Reversing Timer SPIN/DWELLADJUSTMENTSSERVICE/PARTS Information ServiceParts Returning Warranty Parts Warranty InformationReturning Warranty Cards Warranty113222 Routine Maintenance CleaningSuggested Cleaning Schedule Lubrication AdjustmentsData Label Information Heat Input for GAS Dryers Data Label Model NumberProcedure for Functional Check Replacement Components 113222 American Dryer Corp 113222 Sensor Activated Fire Extinguishing S.A.F.E. System F.E. System In ActionBefore YOU Start Check Local Codes and Permits InstallationTypical water supply Optional Manual Bypass F.E. System Theory of Operation F.E. System Water Valve Check F.E. System Diagnostics Messages ADC Part No 06/03/08