American Dryer Corp AD-24 Phase 7 installation manual Section, Safety Precautions

Page 7

SECTION I

SAFETY PRECAUTIONS

WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life.

WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT.

A.Keep dryer area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

B.Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the user smells gas. The instructions should be posted in a prominent location.

C.WHAT TO DO IF YOU SMELL GAS:

1.DO NOT try to light any appliance.

2.DO NOT touch any electrical switch.

3.DO NOT use any phone in your building.

4.Clear the room, building, or area of ALL occupants.

5.Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

6.If you cannot reach your gas supplier, call the fire department.

D.Installation and service must be performed by a qualified installer, service agency, or gas supplier.

E.Dryer(s) must be exhausted to the outdoors.

F.Although ADC produces a very versatile dryer, there are some articles that, due to fabric composition or cleaning method, should not be dried in it.

WARNING: Dry only water washed fabrics. DO NOT dry articles spotted or washed in dry cleaning solvents, a combustible detergent, or “all purpose” cleaner.

EXPLOSION COULD RESULT.

WARNING: DO NOT dry rags or articles coated or contaminated with gasoline, kerosene, oil, paint, or wax.

EXPLOSION COULD RESULT.

WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create a fire hazard.

113222 - 5

www.amdry.com

3

Image 7
Contents AD-24 Installation Manual Retain This Manual in a Safe Place for Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check Section Safety PrecautionsAmerican Dryer Corp 113222 71.91 cm SpecificationsSpecifications UNPACKING/SETTING UP Installation ProceduresLocation of the Dryer Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Single Dryer Venting 113222 American Dryer Corp 113222 Important Venting Reminders Electrical Requirements Electrical InformationGas American Dryer Corp 113222 Single-Phase Electrical Lead Connections American Dryer Corp 113222 GAS Information Type of GAS Do not Reduce this Pipe Size Requirement Preoperational Tests Preparation for OPERATION/START-UPBasket Tumbler Coating Preoperational Instructions Coin Models NON-COIN Models Dual Timer DryersShutdown Instructions Reversing Timer SPIN/DWELLADJUSTMENTSService SERVICE/PARTS InformationParts Returning Warranty Parts Warranty InformationReturning Warranty Cards Warranty113222 Cleaning Routine MaintenanceSuggested Cleaning Schedule Lubrication AdjustmentsData Label Information Heat Input for GAS Dryers Data Label Model NumberProcedure for Functional Check Replacement Components 113222 American Dryer Corp 113222 Sensor Activated Fire Extinguishing S.A.F.E. System F.E. System In ActionBefore YOU Start Check Local Codes and Permits InstallationTypical water supply Optional Manual Bypass F.E. System Theory of Operation F.E. System Water Valve Check F.E. System Diagnostics Messages ADC Part No 06/03/08