American Dryer Corp AD-24 Phase 7 Installation, Before YOU Start Check Local Codes and Permits

Page 44

BEFORE YOU START!

CHECK LOCAL CODES AND PERMITS

Call your local water company or the proper municipal authority for information regarding local codes.

IMPORTANT: It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the plumbing installation is adequate and conforms to local, state, and federal regulations or codes.

IMPORTANT: It is the installation or owners responsibility to see that the necessary or required water, water pressure, pipe size, or connections are provided. Manufacturer assumes no responsibility if the S.A.F.E. system is not connected, installed, or maintained properly.

INSTALLATION

1.Requirements

The S.A.F.E. system must be supplied with a minimum water pipe size of 1/2” and be provided with 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) of pressure. For use of optional manual bypass, a second source with the same piping and pressure requirements is required.

Flexible 1/2 feeds must be provided to avoid damage to electric water solenoid valve by vibration.

IMPORTANT: Flexible supply line/coupling must be used. Solenoid valve failure due to hard plumbing connections WILLVOID WARRANTY.

If the rear area of the dryer, or the water supply is located in an area where it will be exposed to cold/freezing temperatures, provisions must be made to protect these water lines from freezing.

WARNING: If the water in the supply line or water solenoid valve freezes, the S.A.F.E. system will be INOPERATIVE!!

IMPORTANT: Appliance is to be connected to the water mains using a new hose set and the old hose set should not be reused.

40

American Dryer Corp.

113222 - 5

Image 44
Contents AD-24 Installation Manual Retain This Manual in a Safe Place for Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check Safety Precautions SectionAmerican Dryer Corp 113222 Specifications 71.91 cmSpecifications Location of the Dryer Installation ProceduresUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Single Dryer Venting 113222 American Dryer Corp 113222 Important Venting Reminders Electrical Information Electrical RequirementsGas American Dryer Corp 113222 Single-Phase Electrical Lead Connections American Dryer Corp 113222 GAS Information Type of GAS Do not Reduce this Pipe Size Requirement Preparation for OPERATION/START-UP Preoperational TestsBasket Tumbler Coating Preoperational Instructions Coin Models Dual Timer Dryers NON-COIN ModelsReversing Timer SPIN/DWELLADJUSTMENTS Shutdown InstructionsParts SERVICE/PARTS InformationService Warranty Information Returning Warranty CardsWarranty Returning Warranty Parts113222 Suggested Cleaning Schedule Routine MaintenanceCleaning Adjustments LubricationData Label Information Data Label Model Number Heat Input for GAS DryersProcedure for Functional Check Replacement Components 113222 American Dryer Corp 113222 F.E. System In Action Sensor Activated Fire Extinguishing S.A.F.E. SystemInstallation Before YOU Start Check Local Codes and PermitsTypical water supply Optional Manual Bypass F.E. System Theory of Operation F.E. System Water Valve Check F.E. System Diagnostics Messages ADC Part No 06/03/08