American Dryer Corp AD-24 Phase 7 Reversing Timer SPIN/DWELLADJUSTMENTS, Shutdown Instructions

Page 32

REVERSING TIMER SPIN/DWELLADJUSTMENTS

Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear area of the dryer.

Both the Dwell (stop) Time and the basket (tumbler) Spin Time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).

TIMING LEGEND

 

 

 

SPIN TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjustment Position Number

1

2

 

3

4

5

 

 

 

 

 

 

 

Time in Seconds*

30

60

 

90

120

150

 

 

 

 

 

 

 

DWELL (STOP) TIME

 

 

 

 

 

 

Adjustment Position Number

1

2

 

3

4

5

 

 

 

 

 

 

 

Time in Seconds*

5

6.3

 

7.6

8.9

10.2

 

 

 

 

 

 

 

* Values shown are +/- 1-second.

 

 

 

 

 

 

 

 

 

 

 

 

K. SHUTDOWN INSTRUCTIONS

If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:

1.Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.

2.Discontinue the gas supply (for gas models only):

a.SHUT OFF external gas supply shutoff valve.

b.SHUT OFF internal gas supply shutoff valve located in the gas valve burner area.

28

American Dryer Corp.

113222 - 5

Image 32
Contents AD-24 Installation Manual Retain This Manual in a Safe Place for Future Reference For Your Safety Page Table of Contents Section Procedure for Functional Check Safety Precautions SectionAmerican Dryer Corp 113222 Specifications 71.91 cmSpecifications Location of the Dryer Installation ProceduresUNPACKING/SETTING UP Dryer Enclosure Requirements Fresh AIR Supply Requirements Exhaust Requirements Single Dryer Venting Single Dryer Venting 113222 American Dryer Corp 113222 Important Venting Reminders Electrical Information Electrical RequirementsGas American Dryer Corp 113222 Single-Phase Electrical Lead Connections American Dryer Corp 113222 GAS Information Type of GAS Do not Reduce this Pipe Size Requirement Preparation for OPERATION/START-UP Preoperational TestsBasket Tumbler Coating Preoperational Instructions Coin Models Dual Timer Dryers NON-COIN ModelsReversing Timer SPIN/DWELLADJUSTMENTS Shutdown InstructionsParts SERVICE/PARTS InformationService Warranty Information Returning Warranty CardsWarranty Returning Warranty Parts113222 Suggested Cleaning Schedule Routine MaintenanceCleaning Adjustments LubricationData Label Information Data Label Model Number Heat Input for GAS DryersProcedure for Functional Check Replacement Components 113222 American Dryer Corp 113222 F.E. System In Action Sensor Activated Fire Extinguishing S.A.F.E. SystemInstallation Before YOU Start Check Local Codes and PermitsTypical water supply Optional Manual Bypass F.E. System Theory of Operation F.E. System Water Valve Check F.E. System Diagnostics Messages ADC Part No 06/03/08