3M eg4, eg3 user manual Dosimeter fields explained for the Edge

Page 31

25

Customizing set-up parameters in DMS

Dosimeter setting

Dosimeter settings for the Edge

Name Field

 

 

*Note: refer to Glossary for more detailed information.

 

Heartbeat enable

When enabled (or checked), the LED will flash green while running

 

 

and flash amber when stopped.

 

Response

Either Slow Time Response or Fast Time Response is applied to

 

 

the measurements. (Typically Slow time response is used in the

 

 

US market while Fast is used in the EU communities.)

 

C-A enable

When enabled (or checked), C minus A will be calculated.

 

Projected Time

A selectable time parameter via the up/down arrows or type in a

 

 

value. The projected time value is used to make projected dose

 

 

calculation for the dose measurement.

 

Peak Weighting

Select either A, C or Z for the peak frequency weighting.

 

 

 

 

Dose indicator LED

When enabled (or checked), the LED will flash red when the dose

 

 

value exceeds the designated entered value.

 

Setup name

(Optional field) A setup name may be entered into the Meter 1

 

 

and/or Meter 2 fields. When set, it appears on the top of Edge’s

 

 

display (example setup names: OHSHA, MSHA, EU directive).

 

Threshold enable

When the checkbox is selected and a value is entered for meter 1

 

 

and/or meter 2, the threshold is used to calculate Lavg, TWA, and

 

 

 

 

Dose measurements.

 

Upper Limit

Select a UL dB level by the up/down arrows or by typing in a value.

 

 

(Note: The upper limit (UL) is a measurement setting in which the

 

 

user selects a specific decibel level. The UL value records the

 

 

amount of time that the Sound level is at or greater than the

 

 

entered level.)

 

RMS Weighting

Select either A or C RMS Weighting. (Note: The RMS (root mean

 

 

square) are the results from the Edge with the response time and

 

 

weighting settings taken into account.)

 

Criterion Level

Select a Criterion level via the up/down arrow or by typing in a

 

 

value. (Note: Criterion level is the average SPL that will result in

 

 

100% dose over the criterion time and is typically set by a

 

 

regulatory agency such as OSHA, EU directive.)

 

Exchange Rate

Enter in (or select with up/down arrows) 3, 4, or 5 dB. ER refers to

 

 

how sound energy is averaged over time. (OSHA uses a 5 dB

 

 

doubling rate while most of the world uses 3 dB.)

 

Table 1-2: Dosimeter fields explained for the Edge

053-644, Rev E

Page 25

eg4 & eg3

Image 31
Contents Edge 3MTMDetection Mangement Software DMS Introduction DosimetryGetting started Checking the equipment Turning on Turning off Display and keypadRunning studies Noise studiesViews on the Edge DockingUser Interface Appendix a Specifications StandardsStopping a study Technical SupportContacting 3M Quest Technologies International customers Physical attributes of EdgeDock1 and EdgeDock5INDEX………………………………………………………………………………… List of Tables Introduction Illustration of how the dosimeter operates and processes Range of sound Time history manufacturing Peak Measurement 121.20 dB Develop corrective actions Setting-up your dosimeter parameters for your noise studiesRunning your studies View your results via QSP-IIParameter setup screen for eg4 Getting started Powered on with measurement view displayed Edge LED Explanation Indicator LED indicators explainedEdge Keypad EdgeDock1 EdgeDock1 and EdgeDock5 components Attaching charger adapter to EdgeDock1 and EdgeDock5  Powering EdgeDock1 or EdgeDock5Docking the Edge with a single and 5-bay docks  How to chargeBackside of EdgeDock1 Setting-up the Edge via DMS Sample summary data from DMS reporting Logging Dosimeter views and definitions Views on ExplanationResponse Level WeightingViews on Explanation Edge DoseDosimeter measurement descriptors/variants Descriptors Variants Lmax variantsCommunicating connecting a docked Edge to a pc New Hardware wizard for Edge Dock Dosimeter screen Dosimeter fields explained for the Edge Edge display screen Edge security setting Edge auto run screen 10 Edge firmware update screen 11 Saving and sending Edge setups Quick help list for running a study Quick Help List typical dosimetry sessionPositioning/Attaching the Edge  How to attach the dosimeterBattery indicators  Checking battery powerCalibrating  Calibrating the dosimeterOn/off enter  ResetOn/off/enter button  ContrastContrast icon Checkmark icon Is the selection to Display screen while running  How to run a noise studyIndicator Icon Explanation  How to stop a noise studyIndicators i.e., run, stop, battery, and OL Measurement view on the Edge  Viewing measurements How to unlock  How to lock or secureCommunicating between your pc and the Edge  DownloadingDMS start screen  Selecting and viewing data Recent downloaded dataExample of Edge Report in DMS Panel layout view viewing the data in charts and graphs Technical Support  Attaching/Detaching the windscreen and microphone Microphone and windscreen assemblyHard Hat Attachment Kit Weight HousingSize Operating LifeType Memory capacitySize of EdgeDock1 LED amber indicatorLED Red indicator LED Green indicatorRMS Range Status indicatorsDisplayed Data DosimetersAuto-Run SecurityLogging eg4 only Analog Board Edge Block Diagram International customers Service Department and Technical Support 1 800Background Noise, effects Crest Factor Combining Noise sourcesCriterion Level CL Exchange Rate ER also known as the Doubling Rate Criterion TimeDecibel dB DoseLep,d Free field setting microphoneHearing Conservation HC Hertz Hz Lavg Average LevelMeasurement Range Leq Equivalent LevelLogging Maximum Level LmaxResponse Time PEL Permissible Exposure LevelProjected Time Random incidence microphoneThreshold TWA Time Weighted AverageUpper Limit UL Weighting A, C, Z, etcWindscreen Dose = Edge Dock IndexRunning studies QSP-II